VPG – Ring Torsion Load Cell
Brand: VPG
Description:
The RLC is a low profile, high-performance stainless steel ring torsion type load cell. The fully welded construction and glass-to-metal cable entry ensure that this product can be used successfully in harsh environments found in the food, chemical and allied process industries. This product is suitable for small and medium platform scales, hoppers and process weighing. This product meets the stringent Weights and Measures requirements throughout Europe and the USA.
Features:
• Capacity range: 250 kg to 60 t • Low proile, stainless steel construction • Hermetically sealed, IP66 and IP68; IP69K is available for 250 kg, 5 t and 10 t versions • Meets OIML R-60 and NTEP 6000d • Outputs are matched to ensure easy and accurate parallel connection of multiple load cells • Optional: |
|
❍ ATEX certiied versions are available for use in potentially explosive atmospheres ❍ Multi-interval and multiple-range versions are available |
PARAMETER | VALUE | UNIT | |||
Standard capacities (Emax) | 0.25, 0.5, 1, 2, 3.5, 5, 10, 28, 60 | t | |||
Accuracy class according to OIML | NTEP IIIL | D3 | C3(3) | C6(2) | |
Maximum no. of verfication intervals (nlc) | 10000 | 3000 | 6000 | ||
Minimum verification interval | Emax/10000 | Emax/15000 | |||
Minimum verification interval type MR | Emax/20000(1) | Emax/28000 | |||
Rated output (=S) | 2 (1.75 for 0.25 t, 2.05 for 10 t) | mV/V | |||
Output accuracy for multiple LC systems | 0.01 | ±% mV/V | |||
Zero balance | 1.0 | ±% FSO | |||
Combined error | 0.0200 | 0.0300 | 0.0230 | 0.0115 | ±% FSO |
Creep error (30 minutes) | 0.0245 | 0.0123 | ±% FSO | ||
Temperature effect on zero | (0.0010) | (0.0010) | 0.0070 | 0.0045 | ±% FSO/5°C (/°F) |
Temperature effect on sensitivity (output) | (0.0008) | (0.0008) | 0.0050 | 0.0025 | ±% FSO/5°C (/°F) |
Minimum dead load | 0 | % Emax | |||
Maximum safe overload | 150 | % Emax | |||
Ultimate overload | 300 | % Emax | |||
Maximum safe side load |
100% up to 10 t 50% for 28 & 60 t |
% Emax | |||
Deflection at Emax | 0.12–0.20 | mm | |||
Excitation voltage | 5 to 15 | V | |||
Maximum excitation voltage | 30 | V | |||
Input resistance |
1110±50 (1100±50 for 0.25 t and 10 t) 1075±100 for 28 t 1350±100 for 60 t |
Ω | |||
Output resistance |
1025±25 (1025±50 for 0.25 t and 10 t) 930±0.5 for 28 t 1175±0.5 for 60 t |
Ω | |||
Insulation resistance | ≥5000 (20 for 28 and 60 t) | MΩ | |||
Compensated temperature range | -10 to +40 | °C | |||
Operating temperature range | -30 to +70 | °C | |||
Storage temperature range | -50 to +80 | °C | |||
Element material (DIN) | Stainless steel 1.4542 | ||||
Sealing (DIN 40.050 / EN60.529) | IP66 and IP68; IP69K available for 250 kg, 5 t and 10 t | ||||
Recommended torque on fixation bolts | 12 to 14 | N*m | |||
ATEX opt. for potent. explosive atmo-spheres | II2G EEx ib IIC T4/T6, II2D, IIID T70 II3G nA II T4/T6 |