Description
Description
The Simple Logger II family of data loggers is a product line benefiting from advanced design and an excellent quality/price ratio when their specifications and functions are taken into account. The Simple Logger II L101 is ideal for the following applications: representation of the load, detection of fault currents or intermittent problems, monitoring of the neutral current and harmonic currents with DataView.
Specifications:
1 BNC channel
Output voltage range of the current sensor: 0 to 1 V
Resolution: 0.1 mV
Sampling rate: 64 samples/period
Storage interval: programmable from 125 ms to 1 day
Recording modes: Start/End, FIFO, XRM extended mode, on Alarm
Recording duration: 15 minutes to 8 weeks, programmable with DataView
Memory: 240,000 measurements (512 kB)
Communication: optically-isolated USB 2.0
Power supply/battery life: 2 x AA 1.5 V batteries / 100 hrs to more than 45 days