TSURUGA MODEL NRE-65AH/NRE-65AHL

TSURUGA MODEL NRE-65AH/NRE-65AHL

Category: Meter Relay Available
For more information, visit our official website at improtechonline.com

Description

・Lineup with 3 edgewise types of Meter Relay.
・Suitable for display and control of tank capacity and level.
・Bright panel surface and easy to read values.

Specification / Model NRE-65AH
NRE-65AHL
NRE-100AH
NRE-100AHL
NRE-152H
NRE-152HL
NRE -
   
① Size
65A
100A
152
 
② Setting
HL
H


 
H : High value setting, relay contact output HL : High and Low value setting, relay contact output
Dimension
(mm)
22(W)×65(H) - -
30(W)×100(H) - -
50.7(W)×152.3(H) - -
Weight
(1 mA d.c. rated)
  approx. 150 g approx. 320 g approx. 1,300 g
TYPE Edgewise
Input (*1) DC Current (Moving coil) 10 μA - 1A 100 μA,
1mA,
10 mA - 1 A
1 mA
DC Voltage (Moving coil) 10 mV - 300 V 1 V - 300 V
Process (Moving coil) 4 - 20mA,
1 - 5 V(500kΩ)
4 - 20mA,
1 - 5 V(4kΩ),
1 - 5 V
(w / 1MΩ / 7331)
4 - 20mA,
1 - 5 V(4kΩ),
1 - 5 V(1MΩ)
AC Current (average) 1 - 300mA
(w / 7331)
1 - 300mA 1mA
(r.m.s., 1A or more) 1 - 30 A
( w / 7311)
1 - 5 A
(CT incorporated),
10 -30 A
(w / 7311)
AC Voltage (average) 10 - 300V
Display Accuracy Class 1.5 -
Class 2.5 - -
Scale length 44 mm 82 mm 100 mm
Scale divisions 20 - 37.5 -
30 - 50 - -
Scale Pointer Needle type, red Flat Type, red Large type, red
Scale plate color White
Cover color Black - -
7.5BG4/1.5 - -
Transparence
(non-electrification resin)
-
Output Operation type Optical -
Electrical - -
Output Hold (relay)
Pointer Knife shape H(High) : Red, L(Low) : Green
Setting range 0 - 100% of scale for H and L
Setting HL (High / Low ) or H (High)
minimum setting range(*2) Less than 3 %
Pick up accuracy(*2) Less than 2.5 % Less than 1.0 %
Deadband (*2) Less than 0.5 %
Temp. coefficient (*2)
(pick up value change at rated voltage ± 10 %)
Less than 0.5 % Less than 0.3 %
Power regulation (*2)
(pick up value change at rated voltage ± 10 %)
Less than 0.5 % Less than 0.3 %
Output contact 1 transfer for H and L
(NRE-152: N/O or N/C selectable)
Contact rate (load resistance) 250 V, 2 A a.c.
220 V, 2 A d.c.
230 V, 3 A a.c.
30 V, 3 A d.c.
230V, 2.5A a.c.
30V, 2.5A d.c.
100/110,200/220V AC (w / transformer **) ●(*3) ● (*4)
24V DC
Power consumption approx. 2VA 2.5VA or less 3VA or less
Operating temperature 0 – 50°C
Operating humidity 30 - 90%RH (no condensation)
*1
When the rated input exceeds the specific standard, accessory is included with product.
*2
It is the value against the scale length.
*3
The power supply terminal is not insulated from the measurement input terminal. If the transformer is not used, insulate the measurement input from the power supply.
*4
The power source and the input are not insulated in the receiver (1 to 5V, 1MΩ). Insulate the measurement input and power supply when needed.

●:Standard, ○:Option

Customers are requested to provide the following information during order.

  1. 1. Model ( HL or H )
  2. 2. Rated value (Input signal with AC or DC type)
  3. 3. Scale and Unit
  4. 4. Position (Horizontal or Vertical )
  5. 5. Power supply
    ・AC 100/110 V ± 10% or AC 200/220 V ± 10% ( 50/60 Hz )
    ・DC 24V ± 10%

More detail about TECH IMPRO AUTOMATION SOLUTION SDN BHD
TECH IMPRO AUTOMATION SOLUTION SDN BHD
TECH IMPRO AUTOMATION SOLUTION SDN BHD Industrial Automation Supplier Malaysia, Flow Meter Supply Penang, Pressure Transmitter Supplies Butterworth ~ TECH IMPRO AUTOMATION SOLUTION SDN BHD
Contact Us flagMalaysia