Note: Auxiliary unit 2422 is used together with the main unit 2411 or 2421. It can not be connected to some of AC input models.
Product Name | 1ch Main Unit | 2ch Main Unit | 2ch Auxiliary Alarm Output Unit | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Model Configuration |
|
|
|
Code | 2411 | 2421 | 2422 |
---|---|---|---|
D | Digital switch setting | ||
S | Screw driver setting |
Code | 2411 | 2421 | 2422 |
---|---|---|---|
1 | H Setting, relay contact output | HL Setting, relay contact output | |
2 | L Setting, relay contact output | HH Setting, relay contact output | |
3 | H Setting, open collector output | LL Setting, relay contact output | |
4 | L Setting, open collector output | HL Setting, open collector output | |
5 | -------------------- | HH Setting, open collector output | |
6 | -------------------- | LL Setting, open collector output |
Code | 2411 | 2421 | 2422 | |
---|---|---|---|---|
-- | DC signal |
Note: 2422 is the auxiliary unit, so it accepts no input signal and no specification of ③ is required. |
||
02 | DC 0 to 100 mV | |||
03 | DC 0 to 1 V | |||
04 | DC 0 to 5 V | |||
05 | DC 0 to 10 V | |||
09 | DC 1 to 5 V | |||
00 | Other DC voltage input (60 mV≦00 ≦300 V) | |||
22 | DC 0 to 100 μA | |||
23 | DC 0 to 1 mA | |||
24 | DC 0 to 5 mA | |||
25 | DC 0 to 10 mA | |||
29 | DC 4 to 20 mA | |||
20 | Other DC current input (100 μA≦20 ≦1 A) | |||
- | AC signal (Effective value rectification type) | |||
44 | AC 0 to 150 V rms | |||
46 | AC 0 to 300 V rms | |||
40 | (100 mV≦40≦300 V) | |||
53 | AC 0 to 1 A rms | |||
54 | AC 0 to 5 A rms | |||
50 | (100 mA≦50≦5 A) | |||
- | AC signal (Rectification type) | |||
73 | AC 0 to 1 A | ※Half wave peak detection system | ||
74 | AC 0 to 5 A | |||
70 | (100 mA≦70 ≦5 A) |
※Connection with 2422, 2ch Auxiliary Alarm Output Unit,is not possible.
Specification / Model | 2411D/2411S | 2421D/2421S | 2422D/2422S | ||
---|---|---|---|---|---|
D : Digital switch setting S : Screw driver setting |
|||||
Dimension (W x H x D mm) excl .Base socket | 28.5 × 72 × 115 | ||||
Input | DC current / voltage(Moving coil) | ● | ● | - | |
Process | ● | ● | - | ||
AC current / voltage | ● | - | - | ||
Output | Nos. of Alarm | 1point | ● | - | - |
2points | - | ● | ● | ||
Accuracy | Setting (exclude pot.setting) | within ± 0.5 % of Max.value | |||
Repeatability | within ± 0.1 % | ||||
Output | Relay | ● | ● | ● | |
Open collector | ○ | ○ | ○ | ||
Setting style | Thumb | ● | ● | ● | |
Potentiometer | ● | ● | ● | ||
Alarm type (H/L) | H or L fixed | ● | ● | ● | |
Rating | Relay | 250 V, 0.5 A a.c., 30 V, 2 A d.c. | |||
Open collector | 50 V, 100 mA d.c. | ||||
Response |
|
||||
Function | Hysteresis | ○ | ○ | ○ | |
Output delay | ○ | ○ | ○ | ||
Power on delay | ● | ● | ● | ||
Operating temperature | 0-50°C | ||||
Operating humidity | 30 - 90%RH (no condensation) | ||||
AC power supply | 85 – 264 V a.c. | ||||
DC power supply | 20 – 30 V d.c., 90 – 170 V d.c. | ||||
Weight | approx. 170 g |
●:Standard, ○:Option