APPLICATIONS:
DESCRIPTION & FEATURES:
Output Signal |
Standard 2-wire: 4-20 mA / Vs = 8-32 Vdc Optional 3-wire: 0-10 V / Vs = 14-30 Vdc Optional 3-wire ratiometric: Vsig = 0.5-4.5 V / Vs = 5 ± 0.5 Vdc |
Accuracy | ±0.5% FSO |
Permissible Load |
2-wire: Rmax = [(Vs – Vs min) / 0.02] Ohm 3-wire: Rmin = 10 kOhm |
Influence Effects |
Supply: 0.05% FSO / 10 V Load: 0.05% FSO / kOhm |
Response Time |
2-wire: <10 ms 3-wire: <3 ms |
Measuring Rate | 1 kHz |
Thermal Error | <±0.3% FSO / 10K in compensated range 32°F to 158°F (0°C to 70°C) |
Permissible Temperatures |
Medium: -13°F to 185°F (-25°C to 85°C) Electronics environment: -13°F to 185°F (-25°C to 85°C) Storage: -40°F to 185°F (-40°C to 85°C) |
Short-circuit Protection |
Permanent 3-wire ratiometric: None |
Reverse Polarity Protection | No damage. No function. |
Electromagnetic Protection | Emission and immunity according to EN 61326 |
Stability |
Vibration: 10 g, 25 Hz to 2 kHz according to DIN EN 60068-2-6 Shock: 100 g / 1 ms according to DIN EN 60068-2-27 |
Pressure Port / Housing | 304 SS |
Wetted Parts |
Seals: FKM (standard) Diaphragm: 316L SS |
Weight | 120 g |
Current Consumption |
2-wire: 25 mA max 3-wire voltage: 5 mA (short-circuit current 20 mA) 3-wire ratiometric: 1.5 mA |
CE Conformity | EMC directive: 2004/108/EC |