APPLICATIONS:
DESCRIPTION & FEATURES:
Output Signal |
Standard 2-wire: 4-20 mA / Vs = 12-28 Vdc Optional 3-wire: 0.5-5.5 Vdc / Vs = 9-28 Vdc 3-wire: 1-11 Vdc / Vs = 14-28 Vdc Note: Other output signals available |
Accuracy | ±0.25% BFSL / ±0.5% for vacuum only |
Temperature Ranges |
Operating: -40°F to 160°F (-40°C to 71°C) Compensating: 30°F to 160°F (-1°C to 71°C) Storage: -40°F to 185°F (-40°C to 85°C) |
Temperature Shift | 0.0125% per °F over compensated range 75°F (24°C) reference |
Vibration | 15 g / 10 to 2,000 Hz (MIL-STD-202) |
Shock | 50 g / 11 ms (MIL-STD-202, M213, Cond. G) |
Pressure Connection | 1/4″ NPTM, 1/2″ NPTM optional |
Housing | 304 SS |
Wetted Parts |
316 SS diaphragm and 17-4PH SS process connection |
Proof Pressure | 2 x rated pressure or 13,000 psi max |
Current Supply | 3 mA maximum (no load) |
Protection | EMI, ESD and RFI reverse polarity protected |
Approval |
cULus approved as telemetering equipment for use in hazardous locations (UL File E146589, WYMV, WYMV7) as follows: Class I, Div. 1, Groups A, B, C & D Class II, Div. 1, Groups E, F & G CRN registered |
Weight |
7.4 oz. (210 grams): ≤1,000 psi 9.9 oz. (281 grams): ≥2,000 psi |