DIGITAL MULTIMETER DT4261

DIGITAL MULTIMETER DT4261

Category: Digital Multimeter Available
For more information, visit our official website at accutac.com.my

Description

DIGITAL MULTIMETER DT4261

Analyzing Issues in the Field and Dramatically Improving Work Efficiency

Hioki mid-range DMM, the DT4261, is an exceptional support tool with multifaceted functionality designed to help analyze a variety of issues and boost work efficiency.

CAT III 1000 V, CAT IV 600 V

Key Features

 

Basic specifications

Accuracy guaranteed: 1 year, Accuracy guarantee period after adjustment made by Hioki: 1 year
DMM Accuracy: Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the brochure for detailed accuracy information.
 
DC Voltage range 600.0 mV to 1000 V, 5 ranges. Basic accuracy: ±0.15% rdg. ±2 dgt.
AC Voltage range 6.000 V to 1000 V, 4 ranges. Frequency characteristics: 40 Hz to 1 kHz. Basic accuracy (40 Hz - 500 Hz): ±0.9% rdg. ±3 dgt. (True RMS, crest factor 3 or less)
DC + AC Voltage range 6.000 V to 1000 V, 4 ranges. Frequency characteristics: DC, 40 Hz to 1 kHz. Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less)
LoZ V 600.0 V, 1 range. Frequency characteristics: DC, 40 Hz to 1 kHz. Basic accuracy DC, 40 Hz - 500 Hz: ±1.0% rdg. ±13 dgt. (True RMS, crest factor 3 or less)
Resistance range 600.0 Ω to 60.00 MΩ, 6 ranges. Basic accuracy: ±0.7% rdg. ±3 dgt.
DC Current range 600.0 mA to 10.00 A, 3 ranges. Basic accuracy: ±0.5% rdg. ±3 dgt.
AC Current range 600.0 mA to 10.00 A, 3 ranges. Basic accuracy (40 Hz - 500 Hz): ±1.4% rdg. ±3 dgt. (True RMS, crest factor 3 or less). Frequency characteristics: 40 Hz to 1
AC Current range (use with Clamp on probes) 10.00 A to 1000 A, 7 ranges
Basic accuracy 40 Hz - 500 Hz: Add the Clamp on probe accuracy to ±0.9% rdg. ±3 dgt.
(True RMS, crest factor 3 or less)
Capacitance range 1.000 µF to 10.00 mF with 5 ranges. Basic accuracy: ±1.9% reading ±5 digits
Continuity Check Threshold ON: 25 Ω, Threshold OFF: 245 Ω. Response time: 0.5 ms or more
Diode Test Open terminal voltage: 2.0 V or less, Testing current: 0.2 mA or less. Threshold of forward voltage: 0.15 V to 1.8 V