FC1000 Standard type weighing indicator

FC1000 Standard type weighing indicator

Category: weighing indicator Available
For more information, visit our official website at ims.com.my

Description

FC1000 is the weighing indicator with various features such as the white LCD main and sub display, dust and drip protection (Equivalent to IP65), accumulation function, data recording on SD Card, and high-speed A/D conversion rate of 1.2kHz.

 



SD card slot
You can write and read setting parameters from SD cards, while recording weighing results & data when abnormalities occur.
 
■ Calibration value & Error logs are automatically recorded
 You can identify the indications of faulty load cells and replacement timing.
 Date & time of errors occurred can be displayed, as well as the record of how the errors are made (through key control, communication, I/O, etc).
 
■ Data recording of weighing results
 Monitor management of raw material, equipment operation rate and so on.
 Long-term trend can be observed as well.
 
■ Restore setting parameters with just one touch
 ・You can copy setting parameters to another replaced FC1000.
 ・Multiple FC1000s can use the exact same settings.
 ・You can restore the initial setting when you first install FC1000. (It will be saved as initial value separately from the setting parameters).

Depth of 99mm
Miniaturization of control panel & panel space saving.
 
High performance filter & Auto filter adjustment
With combination of low pass filter (0.1 to 300Hz) which corresponds to various vibration and moving average filter (OFF, 2 to 512) that is effective for periodic vibration, automatic searching for optimal value with accuracy and stability can be achieved. (You can manually adjust settings too).

 
 
Minus compensation
High-pressure liquid filling & powder feeding can be done.

Equivalent to IP65 protection
By placing the rubber seal when mounting on the panel, the front panel can be protected from moisture and dust damage.
 
High sampling rate & resolution
High performance digital low-pass filter can be adjusted at 0.1Hz increment. As it is resistant to vibration, measurement can be performed quickly and precisely.
 
Load cell signal level display (-2.51mV/V to 5.1mV/V)
The output signal level of load cell can be displayed in mV/V for monitor purpose.
Malfunction indicator or faulty sensor can be differentiated easily.
 
Total weight control function
The batch weighing with a low capacity scale enables the fast and accurate measurement of larger total weight.

Bright white LCD display with the useful 20 digits sub display
The sub display can be used to show the cumulative weight, code/preset number, etc….


 
6 digit display
24 bit A/D convertor enables 6 digit display.
 
Memory for 32 weight settings
32 different weight settings can be saved in the memory and selected through I/O or interface.
Batch weighing can be performed easily.
 
Equivalent input calibration
Theoretical calibration can be performed easily by registering the capacity and rated output of load cells.
 
Multipoint calibration (linearization)
Three additional points can be defined in the middle between zero and span for better linearity.
Even though the scale has poor linearity, it can be corrected to be a highly accurate scale.



Analog section
Excitation voltage DC5V±5% Output current:90mA
Remote sense type (Up to 6 350Ω load cells can be connected in parallel)
Signal input range -2.5 to +5.1mV/V
Zero adjustment range Automatic adjustment by digital processing -2.5 to +2.0mV/V
Span adjustment range

Automatic adjustment by digital processing 0.02 to +3.0mV/V

Linearization function Up to three point multi-point calibration is possible
Min. input sensitivity 0.15μV/count
Accuracy Non-linearity: within 0.01%FS
Zero drift: 0.0002%FS/℃ Typ
Gain drift: 1ppm/℃ Typ
Filter Digital low-pass filter 0.1 to 300.0 Hz
Moving average filter OFF, 2 to 512 times
A/D converter Speed: 300 times/sec., 1200 times/sec.
Resolution: 24bit binary
 
Display section
Display Unit 7-segment LCD display
Main display: 8 digit(14.4mm character height),
Sub-display: 20 digit (4.3mm character height)
Display value 5 digit sign: negative display at the highest digit (Up to 6 digits)
Unit None / kg / g / t / lb / N
Decimal point 0, 0.0, 0.00, 0.000
Weight errors “LOAD”: sensor signal level is above the signal input range,
“-LOAD”: the sensor signal level is below the signal input range,
“OFL1”: the Net weight is over the limit,
“OFL3”: the GROSS weight is over the limit
Display frequency 1, 3, 6, 13 or 25 times/sec.
Status display SP1 / SP2 / SP3 / COMPLETE / TARE ON / NET / OUT1 / OUT2
 
Setting section
Setting method By operating the membrane keys or through interface
Memory of set value Default settings: stored in NOV.RAM (non-volatile RAM)
Time: backed up by lithium battery
Other setting values: stored in F-RAM (non-volatile RAM)
Protection of set value Settings can be protected with the software LOCK
Setting item – Upper limit / Lower limit / Near zero / Set point 1 / Set point 2 / Compensation / Over / Under / Final
– Comparison inhibit time 1 / Judging time / Complete output time / Compensation Feeding Time / Number of times for AZ / Number of times for judging / Auto free fall compensation regulation values / Comparison inhibit time 2 / Preset tare value
– Weighing function 1 / Weighing function 2 / Weighing function 3 / Sequence mode / Key invalid-LOCK / Discharging Time / Motion detection(Period – Range) / Zero tracking (Period) / Zero tracking (Range)
– Balance weight value / Minimum scale division / NET weight over / GROSS weight over /DZ limitation value / Display selection / Gravitational acceleration / Sub-display mode /Sub-display selection
– D/A output mode / D/A zero scale adjustment / D/A full scale adjustment / RS-232C/RS-485 setting / RS-232C/RS-485 ID / Transmission delay time / CC-Link I/F setting / CC-Link station number setting / Setting LOCK
– Input Signal selection 1 / Input Signal selection 2 / Input Signal selection 3 / Output Signal selection 1 /Output Signal selection 2 / Output Signal selection 3 / Output Signal selection 4 / Status display selection / Sampling speed
– Total count / SP0 / Total comparison mode / Target total weight (high 4) /Target total weight (under 5) / Total SP1 (high 4) / Total SP1 (under 5)
– SD card command 1 / SD card command 2 / Time and Date / Auto adjustment filter / Digital low pass filter / Moving average filter / Extended function selection 1 / Extended function selection 2 / Total weight control function
– Average weight value / Maximum weight value / Minimum weight value /General standard deviation / Sample standard deviation / Number of data / Latest data /Maximum-Minimum / Option display
– Span calibration / Equivalent span calibration / Equivalent zero calibration / Linearize calibration 1 / Linearization calibration 2 / Linearization calibration 3 / Linearization Calibration / Calibration Point Confirmation / Password / Zero Calibration
iMS Motion Solution (Johor) Sdn Bhd (Company Registration 1098771-W)
 
No.7, Jalan Sasa 4,Taman Gaya, 81800 Ulu Tiram, Johor Bahru, Johor. Malaysia.
TEL:+607-8635240 FAX: +607-8637240
MOBILE: +6019-6774477
EMAIL: [email protected]WhatsApp  | www.ims.com.my
HOTLINE : 1700-818-330
whatsapp us now !

Brand Name
MEISTER | GGM | Sanyo Denki | ElectroCraft | EDrive | SHIHLIN ELECTRIC | AUTONICS | UI Robot | Mitsubishi CNC | PANASONICApex Dynamics | NISSEI GTR | UNIPULSE | CREVIS
 
MOTION DEVICES SPECIALIST | SYSTEM and CONTROL INTEGRATION |
| Induction Motor | Speed Control Motor | Reversible Motor |Brake Motor |BLDC Motor |DC Motor |Planetary Gear Motor | Servo Motor | Stepping Motor | Linear Actuator Motor | Lead Screw Motor|Close Loop Stepping Motor | Customization Motors | Right Angle Gear Head | Precision Gear Reducer |PLC | Motion Controller |HMI /Touch Screen| Inverter |CNC Controller |Multi Axis Robots |IPC | SCADA |Monitoring Software | Embeded PC | Remote IO |TPC | Motion Card | Loadcell |PPC |
 
Return / Refund Policy : 
All goods sold are not returnable & we accept goods ex-change with equal or lower value of good purchased. If the ex-change items are higher than purchased items, buyer shall top up the differential cost. All payment made are not refundable, please confirm the purchase items code & cost with our sales representative before place orders.
 
Shipping and Fulfillment :
Thank you for your purchase. Once we have confirmed your payment, we will prepare and ship out your order out within 24-48 hours.( For ex-stock items only, Indent items subject to delivery stated in quotation & conversation in emails). Once your order has been shipped out, you will receive an email notification with the tracking number and tracking details inside.
 
Private Policy
General Statement of Principles 
As described in detail below, any information we gather at this web site is strictly for our use and is not shared with any other entity, public or private, for any reason - period. We will not sell or give away any lists or other data that we may retain and we do not purchase such information from other sources.
Statistical Data 
Our servers (as most) track IP addresses and referring pages to help with site maintenance and improvements. This data is viewed only as anonymous statistics to show the busiest times of the day or week, pages with errors and how effective our advertising has been. This information is not used for any other purpose.
Personal Information Collected - Order Forms
With the exception of credit card info, we store the information from your order form to allow us to track consulting issues or refer to a previous order to help provide some customer service. You may elect to have your information completely removed from this system by e-mailing us at [email protected] with your request. We do not store any type of sales information.
Information Correction or Removal 
If you wish to correct, update or remove any information about you that may be in our records, please send us e-mail at [email protected] with the details of your request. If you wish to contact us further, please find complete contact information on our contact page.
Cookies
Cookies are files with small amount of data, which may include an anonymous unique identifier. Cookies are sent to your browser from a web site and stored on your computer's hard drive. We use 'cookies' to store your cart contents for you. You can instruct your browser to refuse all cookies or to indicate when a cookie is being sent. However, if you do not accept cookies, you may not be able to use the checkout section of our site.
 
Changes To This Privacy Policy
This Privacy Policy is effective as of 1st Jan 2019 and will remain in effect except with respect to any changes in its provisions in the future, which will be in effect immediately after being posted on this page.

More detail about IMS Mechatronics Sdn Bhd
IMS Mechatronics Sdn Bhd
IMS Mechatronics Sdn Bhd Motion Solutions Johor, Control Components Supplier Malaysia, Motion Devices Johor Bahru (JB) ~ IMS Mechatronics Sdn Bhd
Contact Us flagMalaysia