Schneider - MiCOM P127

Overcurrent and earth fault protection relay-30 TEStandard display

Schneider Micom P127 relay is part of MiCOM P12x, a range of directional and non-directional overcurrent relays from single-phase or earth fault up to the multifunctional three-phase P127 numerical relay with voltage protection functions. Models available: MiCOM P120, MiCOM P121, MiCOM P122, MiCOM P123, MiCOM P125, MiCOM P126, MiCOM P127

MiCOM P127 is housed in a compact 4U case in 20TE or 30TE widths, Schneider Micom P127 Relay is fully withdrawable to facilitate easy and quick replacement. The dual-rated current input is powered by conventional 1A or 5A Current Transformers. A wide-range power supply allows a flexible auxiliary voltage to be applied from 24-250Vdc/48-240Vac. P122 also offers a compact case solution with reduced hardware and functionality where installation space is minimal.

Software features include 2 settings groups for quick switching between application configurations and customizable reflex automation, allowing logical AND, OR, or NOT gates.

MiCOM P127 devices also include a rear RS485 communication port with a variety of protocols; DNP3, IEC 60870-5-103, Modbus, and Courier.

 



Details

Range of product
-MiCOM P127

Device short name
-P127

Relay application
-Feeder

Protection Type
-Overcurrent ANSI code: 50/51
-Recloser ANSI code: 79
-Cold load pick-up
-Earth fault ANSI code: 50G/51G
-Lockout ANSI code: 86
-Negative sequence overvoltage ANSI code: 47
-Undervoltage ANSI code: 27
-Overvoltage ANSI code: 59
-Rate of change of frequency ANSI code: 81R
-Neutral voltage displacement ANSI code: 59N
-Thermal overload protection ANSI code: 49RMS
-Underfrequency ANSI code: 81L
-Phase undercurrent ANSI code: 37
-Breaker failure ANSI code: 50BF
-Negative sequence overcurrent ANSI code: 46
-Restricted earth fault ANSI code: 64REF
-Directional earth fault ANSI code: 67N
-Directional phase overcurrent ANSI code: 67
-Overfrequency ANSI code: 81O
-Voltage-restrained overcurrent ANSI code: 50V/51V


Number of inputs
-4 current input CT...X/5 A and X/1 A
-3 voltage
-12 discrete

Number of outputs
-9 discrete

Communication port protocol
-DNP3
-IEC 60870-5-103
-Modbus RTU


Complementary

[Us] rated supply voltage
-24...250 V DC 19.2…300 V
-48...250 V DC 38.4…300 V
-48...240 V AC 38.4…264 V

Control and monitoring type
-Circuit breaker/contactor control

Network and machine diagnosis type
-Fault recording
-Event recording
-Disturbance recording15 s

Switchgear diagnosis type
-CT/VT supervision
-Trip circuit supervision ANSI code: TCS

Display type
-Backlit LCD: 2 lines of 16 characters

Discrete input voltage
-24...250 V DC 19.2 V standard variant
-48...250 V AC 19.2 V standard variant
-48...250 V DC 105 V further option
-48...250 V DC 77 V further option
-48...250 V DC 154 V further option

Communication port support
-RS232
-RS485



Environment

Type of measurement
-Current

Height
-177 mm total:
-156 mm embedded:
 
Width
-155 mm
 
Depth
-249.6 mm total:
-223 mm embedded:
 
Device mounting
-Flush

Schneider  / MiCOM P127 / Super Premium Efficiency Motor / High Efficiency Motor/ Electric Efficient Motor supplier in Malaysia.

 Available in Penang, KL, Selangor, Johor & anywhere in Malaysia & Singapore.

 

More detail about Saturn Pyro Sdn Bhd
Saturn Pyro Sdn Bhd
Saturn Pyro Sdn Bhd Energy Meters Supplier Johor Bahru (JB), Energy Management Malaysia, Selangor, Power Quality Analyzers Supply Kuala Lumpur (KL), Penang ~ Saturn Pyro Sdn Bhd
Contact Us flagMalaysia