These new Programmable Climate Cabinets with a precise system of temperature and humidity control, which provide various necessary environmental simulative conditions for industrial research and biotechnology tests. Widely applied in sterile tests and stability check-up of pharmaceuticals, textile and food processing as well as tests in material performance, packing and lifetime of industrial products.
1.0 Structure Feature |
|
Chamber Structure |
Internal material:304# stainless steel with thickness is 1.2mm External material:1.2mm baking finish cold roll steel plate with advanced static electricity spray process. Heat preservation material: polyurethane foam rubber with 100 mm thick Others:install the positioning foot cup and movable trundles under the test chamber bottom; top of chamber equips automatic pressure relief hole, bottom of inner chamber equips drainage hole, can drain out condensate water quickly |
Air Adjustment |
Inside air space, recirculating wind channel and stainless steel cycle fan, through the top window and air diffuser, the wind will out uniformly from the top, let the reconciled temperature from the harmonic room diffuses to the test area, which could reach the purpose of control temperature uniformly. |
Chamber Door |
◆Single open door ◆Anti-explosion ◆Anti-condensation electric heating device ◆Vacuum auto-defog transparent window ◆Window floodlight |
Cable Port |
Install a ¢ 50mm test hole on the left of the machine, and equip related seal device for connecting with power test |
View Window |
designed in the door with 230*270mm transparent electric radiant heating film with cavity toughened glass(equipped with anti-condensation function) |
Control System |
TEMI 1500 Touch Screen LCD, imported from Korea, floodlight switch,main power switch |
Cooling System |
refrigeration system, heating device, fan, dewatering device, adjustable back window |
Sample Shelf |
adopt 304# stainless bent into net sharp, easy for use, the distance between the material frame could be adjusted(the smallest distance is 50mm),standard equipped two pieces |
Electrical Room |
main power breaker, controller, distribution plate, radiating fan, over temperature protector |
Heating System |
adopt the scale heat rejection heating pipe P.I.D. control the heating so let the temperature gets the balance |
2.0 Refrigerating System |
|
Refrigeration Method |
to keep the cooling rate and minimum temperature requirement,we use single stage refrigeration system |
Refrigeration |
adopt low temperature compressor from European |
Cooling System |
air-cooled scale condenser, circulating fan for heat dissipation |
Evaporimeter |
finned tube heat exchanger |
Throttling Device |
thermostatic expansion valve ,capillary tube |
Dry filter |
absorption for the residual water and acidic material from refrigerating fluid in refrigerating system, filtrate the solid impurity grain, copper cuttings of system, keep the normal working of expansion valve and capillary, in case of ice blockage and filth blockage |
Refrigerating Fluid |
adopt environment protected refrigerating fluid R404A |
3.0 Electrical Control System |
|
Controller |
Korea SAMWON, LCD touch screen controller TEMI 1500 |
Display Interface |
◆ Display screen dimension:5.7 inches colorful touch screen conversational mode ◆Temperature set value(SV), current value(PV)displays directly ◆Can display the temperature output value ◆The execute program number, section, procedure time and time signal control condition can be displayed ◆Can display auto-calculus picture and procedure standby light-flooding picture ◆Can display record data and curve condition picture ◆Can display current curve and edit procedure curve and history running curves ◆Can display fault indicated and simple fault exhaust |
Procedure Capacity And Control |
◆Operational procedure capacity:max:120 groups;one procedure could consist of 1 to 99 sections. ◆Operational memory capacity:1200 sections, could repeat executive command: each command could repeat 999 times, the slope setting of the procedure could be set through the timer shaft, the jointing use could be set among the procedures, the procedure making can adopt dialogue type, easy to operate with edit, eliminate and insert function, 4 groups of time signal output control (can control the test sample ON/OFF option). ◆9 groups of PID parameter setting, the procedure will have the overleap section, keep functions; can show the curve and data collection; date and time adjustment function; button and picture lock(LOCK) function; can connect the computer, 8 points of DI abnormal input and 10 points of DO signal control |
Communication |
RS-232 communicate interface, can used as monitoring and remote control system, record the test data |
Running Method |
program mode / definite value mode |
Set Method |
English interface, touch screen input |
SD Storage Card |
Used to store test date and test curve, standard storage capacity is 2G, storage time is about 2 years |
Setting Range |
up/down limitation of maximum temperature range is 5℃ |
Display Resolution |
temperature: 0.01℃; time: 1min; |
Memory Function |
can set recovery mode in case of power off : heating/ cold/ stop |
Make anappointment function |
can set available machine time randomly, after turn on the power, the machine will run automatically |
Input |
PT100 type platinum resistor |
Curve record |
equip with battery protection RAM, can save the set value, sampling value and sampling time of the machine;Max record time is 60 days(when the sampling cycle is 1.5min) |
Software use |
IBM PC compatible machine, above PⅡ CPU, more than 128M RAM, simplified Chinese Windows2000 or simplified Chinese WindowsXP operation system. |
Circulating fan |
low noise with many wing centrifugal fan |
Heater |
import nichrome electronic heater and heater control mode is contactless equal cycle recurrent pulse adjust wide, SSR(solid-state relay) |
Control Mode |
anti-integral saturation PID, BTC balance adjust temperature control mode(temperature test equipment) |
4.0 Humidify and Dehumidify System |
|
Water Supply |
Big water tank |
Humidify And Dehumidify Method |
Adopts outer humidify, compressor start to dehumidify, P.I.D controls the humidify volume to reach the need humidity |
Water Quality |
Resisitivity ≥500Ω·m |
Water Supplement Method |
Chamber reserves the water supplement port and water level viewing window, please supply water when the water level is too low |
Humidify Water |
Inner equipped with a micro water pump, and only needs to add water to the water tank. The water pump is automatically added to the humidifying boiler according to the water level in the humidifying boiler |
5.0 Safety Protection Device |
|
Refrigerating System |
compressor overheat/over current/ over pressure, condensation fan overheat |
Test Chamber |
over temperature limitation, fan/motor over temperature relay |
Power |
earth leakage protection, overload protection, short-circuit protection |
Storage Environmental Requirement |
environmental temperature of the machine keep within 0℃~+40℃ |
Installation Site |
◆ the distance between the wall and left/right/back should be at least 600mm(A/B) ◆ the distance between the wall and the front side of the machine should be at least 1200mm(C) ◆ please make sure the gate, gallery and elevator could pass the machine in case of affect to your company normal working |
■ Temperature Uniformity:± 2 ℃
■ Humidity Uniformity:≤ 2%~3% RH("g 75%RH) or ≤±5% RH(≤75% RH)
■ Temperature Stability:±0.5 ℃
■ Humidity Stability:±2% RH
■ Temperature Increasing Rate:3.5℃/min(no-load, average value during the whole test)
■ Temperature Decreasing Rate:"g1℃/min(no-load, average value during the whole test)
■ Power Supply:220V/380V; 50HZ
■ Total Power:5.5 KW
Ordering |
Temperature |
Humidity Range |
Total Power/Max. Current |
Working Room Size |
Overall Size |
BGD 897/100B |
-20~1500淐 |
20~98% |
4.6KW/16A |
400×500×500mm |
900×1400×1150mm |
BGD 897/100C |
-40~1500淐 |
||||
BGD 897/100D |
-60~1500淐 |
||||
BGD 897/225B |
-20~1500淐 |
5.5KW/22A |
500×750×600mm |
1000×1650×1250mm |
|
BGD 897/225C |
-40~1500淐 |
||||
BGD 897/225D |
-60~1500淐 |
||||
BGD 897/608B |
-20~1500淐 |
11KW/12A (380V; 3 phase and 4 wires) |
800×950×800mm |
1300×1850×1400mm |
Biuged also accept any customized climate chamber(different size and temperature)!!
More detail about LUX & BRILLIANCE TECHNOLOGIES SDN. BHD.