Description
Time before dangerous failure: MTTFd = 100 years
Cycle before dangerous failure: B10d=100,000 at 5A
Risk duration: approx. 2 to 7s adjustable at front
Persistence: approx. 20 mV to 700 mV adjustable front
Motor power: up to 3x690 VAC
Protection for severed wires: yes
Protection against disconnection of motor coiling: yes
Safety contacts: 3x NO 8A/250V redundant
Diagnostics: 1x NF 8A/250V redundant parallel.
1 PNP ''OK'' output indicating motor coiling presence.
1 PNP ''ERROR'' output indicating a synchronization malfunction.
1 ''RS'' system reset input.
Indicators: 3 LEDs for diagnostics
Reset: automatic
Mounting: symmetrical DIN 35mm rail on DIN 50022
Mounting: IP 20 electrical box
Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum
Temperature: -20°C to +60°C