AANDERAA Pressure Based Waves

AANDERAA Pressure Based Waves

Category: PRESSURE BASED WAVES Available
For more information, visit our official website at hsa-asia.com

Specifications
  • Pressure Based Waves: Aanderaa Pressure Based Sensor Smart Sensor technology Plug and Play Sensor Calibration coefficients are stored in the sensor Minimal and simple maintenance needs Low current drain Power: 5 to 14VDC, 50mA max Output formats: AiCaP CANbus, RS-232/RS-422 Short update interval: 1 seconds to 255 minutes 2Hz and 4Hz sampling frequency New updated wave parameters every 1 second 256, 512, 1024 & 2048 samples Outputs: Pressure, Temperature, Tide pressure, Tide Level, Significant wave height, Maximum wave height, Mean Periode, Mean Zerocrossing Periode, Energy Periode, Steepness, Irregularity of sea state, Cut-off frequency, Pressure time series, Last pressure sample index, Wave spectrum Real-time XML output 5218/5218R: Measurement range: 400kPa, 1000kPa Max operating depth: 30m, 90m 4428/4428R/4429/4429R: Compensate for air pressure Measurement range: 50kPa, 100kPa Max operating depth: 5m, 10m
Description

Measure pressure based Waves with the Aanderaa Wave Sensors- compact fully integrated sensors for measuring wave and tide conditions

 

The 5218 wave sensor is designed to be mounted on the Aanderaa SeaGuard top-end plate or connected to SmartGuard using AiCaP CANbus or in other measurement systems using the RS-232 interface.

The 5218R wave sensor sensor is designed for use with long cables by means of RS-422 full duplex interface.

Both wave sensors are based on a silicon piezoresistive pressure sensor. The pressure measurements are sampled and temperature compensated by an advanced Digital Signal Processor.

The wave sensor application areas are in fixed installations, either deployed in a seabed installation in shallow waters, or mounted onto a fixed structure in the upper water column.

The tide measurement is an average of the hydrostatic pressure measured over a time period of 10 seconds to 8 minutes (integration time configurable by the user). The update interval is between 1 second and 255 minutes.

The wave measurements are based on the pressure time series measured over a time period of 64 second to 17 minutes (configurable by the user). The update interval is between 1 second and 255 minutes.

The wave and tide sensor output parameters are:

Since all calibration and temperature compensation data are stored inside the sensor, the parameters are by default presented directly in engineering units without any external calculation. The sensor also provides raw data of the pressure and the temperature measurements.

5218 is a compact yet intelligent sensor designed to be used with Aanderaa SmartGuard or SeaGuard as well as in other measuring systems.

Applications:

More detail about HSA ASIA SDN BHD
HSA ASIA SDN BHD
HSA ASIA SDN BHD Measuring Instruments Selangor | Flow Meter Supply Kuala Lumpur (KL) | Water Analytical Instruments Supplier Malaysia ~ HSA ASIA SDN BHD
Contact Us flagMalaysia