Fluke - 77 IV Digital Multimeter

Fluke - 77 IV Digital Multimeter

Category: Available
Purchasable on official site
For more information, visit our official website at carlssoon-tech.com.my

Description

Fluke  - 77 IV Digital Multimeter
Brand : Fluke
Model : 77 IV

 
Description

The Fluke 77 IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke's original 70 Series with more measurement functions, conformance to the latest safety standards, and a much larger display that's easier to view.

 
Features

The 77 IV replaces the 77. Move up to superior utility and safety today.
 
Specifications
 
Specifications
 
Voltage DC
Range 6.000 V – 1000 V
Best accuracy ±(0.3% + 1)
Best resolution 0.1 mV
Voltage AC Range 600.0 mV – 1000V
Best accuracy ±(2.0% + 2)
Best resolution 1.0 mV
Amps AC Range 60.00 mA – 10 A
Best accuracy 2.5% + 2
Best resolution 0.01 mA
Amps DC Range 60.00 mA – 10A
Best accuracy 1.5% + 2
Best resolution 0.01 mA
Resistance Range 600.0 Ω – 50 MΩ
Best accuracy ±(0.5% + 1)
Best resolution 0.1 Ω
Capacitance Range 1nF – 9,999 μF
Best accuracy ±(1.2% + 2)
Best resolution 1 nF
Frequency Range 99.99Hz – 99.99kHz
Best accuracy ±(0.1% + 1)
Best resolution 0.01 Hz
Safety ANSI / ISA S82.02.01, CSA C22.2–1010.1, IEC 61010 to 1000 V Measurement Category III, 600 V Measurement Category IV
Certifications CSA, TÜV (EN61010), Π, (N10140)
General Specifications
Maximum voltage between any terminal and earth ground 1000 V
Surge protection 8 kV peak per IEC 61010
Ω Fuse for mA inputs 440 mA, 1000 V FAST Fuse
Ω Fuse for A inputs 11 A, 1000 V FAST Fuse
Display Digital 6000 counts, updates 4/sec
Bar graph 33 segments, updates 32/sec
Frequency 10,000 counts
Capacitance 1,000 counts
Altitude Operating 2,000 meters
Storage 12,000 meters
Temperature Operating -10°C to + 50°C
Storage -40°C to + 60°C
Temperature coefficient 0.1 x (specified accuracy / °C (< 18°C or > 28°C)
Electromagnetic compatibility
(EN 61326–1:1997)
In an RF field of 3 V/M, accuracy = specified accuracy except in temperature:
specified accuracy ±5°C (9°F)
Relative humidity
(maximum non-condensing)
90% to 35°C
75% to 40°C
45% to 50°C
Battery life 400 hours typical (alkaline)
Size (H x W x L) 4.3 x 9 x 18.5 cm
Weight 420 g
 