DAIKIN FCFG-REVO MAX SERIES PREMIUM CASSETTE INVERTER

DAIKIN FCFG-REVO MAX SERIES PREMIUM CASSETTE INVERTER

Category: DAIKIN Available (Qty:60) 12 variants are available
TYPE
FCFG50A (2.0HP)FCFG60A (2.2HP)FCFG71A (2.5HP)FCFG85A (3.0HP)
SERVICE
SELF PICK-UPDELIVERY KL.VALLEYWITH INSTALLATION
RM4690.00 - RM6350.00 For more information, visit our official website at metrocool.com.my

Description

PRODUCT DESCRIPTION
 - Revo max inverter surround cassette
 - Single-split inverter series

FEATURES
 - Surround airflow
 - Streamer : decomposition of harmful substances inside
 - Active plasma ion : indoor air cleaning
 - Gin-ion blue filter : advanced filtration
 - Smart control (built in wifi)
 - Inverter technology : optimal comfort,convenience & greater power saving
 - Pcb voltage shield (durable pcb)

SPECIFICATIONS

FCFG50AV1MF-RZFG50AGVMM
PANEL : BCR50GMF

 - Cooling capacity : 18500 btu/h / 5.42 k/w
 - Power : 1680w
 - Sound pressure level(h/l) : 44 dba / 37 dba
 - Dimension(HxWxD)(indoor) : 246mm x 840mm x 840mm / panel 135mm x 962mm x 962mm
 - Weight(indoor) : unit 22.0kg / panel 8.5kg
 - Sound pressure level(outdoor) : 52 dba
 - Dimension(HxWxD)(outdoor) : 615mm x 845mm x 300mm
 - Weight(outdoor) : 37.0kg
 - Pipe connection size(liquid/gas) : 6.4mm / 12.7mm

FCFG60AV1MF-RZFG60AGVMM
PANEL : BCR50GMF

 - Cooling capacity : 20500 btu/h / 6.00 k/w
 - Power : 1960w
 - Sound pressure level(h/l) : 44 dba / 37 dba
 - Dimension(HxWxD)(indoor) : 246mm x 840mm x 840mm / panel 135mm x 962mm x 962mm
 - Weight(indoor) : unit 22.0kg / panel 8.5kg
 - Sound pressure level(outdoor) : 52 dba
 - Dimension(HxWxD)(outdoor) : 615mm x 845mm x 300mm
 - Weight(outdoor) : 37.0kg
 - Pipe connection size(liquid/gas) : 6.4mm / 12.7mm

FCFG71AV1MF-RZFG71AGVMM
PANEL : BCR50GMF

 - Cooling capacity : 24200 btu/h / 7.10 k/w
 - Power : 2070w
 - Sound pressure level(h/l) : 44 dba / 37 dba
 - Dimension(HxWxD)(indoor) : 246mm x 840mm x 840mm / panel 135mm x 962mm x 962mm
 - Weight(indoor) : unit 22.0kg / panel 8.5kg
 - Sound pressure level(outdoor) : 52 dba
 - Dimension(HxWxD)(outdoor) : 615mm x 845mm x 300mm
 - Weight(outdoor) : 37.0kg
 - Pipe connection size(liquid/gas) : 9.5mm / 15.9mm

FCFG85AV1MF-RZFG85AVMM
PANEL : BCR50GMF

 - Cooling capacity : 30000 btu/h / 8.79 k/w
 - Power : 2710w
 - Sound pressure level(h/l) : 44 dba / 37 dba
 - Dimension(HxWxD)(indoor) : 246mm x 840mm x 840mm / panel 135mm x 962mm x 962mm
 - Weight(indoor) : unit 22.0kg / panel 8.5kg
 - Sound pressure level(outdoor) : 53 dba
 - Dimension(HxWxD)(outdoor) : 695mm x 930mm x 350mm
 - Weight(outdoor) : 40.0kg
 - Pipe connection size(liquid/gas) : 9.5mm / 15.9mm

FCFG100AV1MF-RZFG100AY1M
PANEL : BCR50GMF

 - Cooling capacity : 36000 btu/h / 10.55 k/w
 - Power : 3470w
 - Sound pressure level(h/l) : 48 dba / 43 dba
 - Dimension(HxWxD)(indoor) : 288mm x 840mm x 840mm / panel 135mm x 962mm x 962mm
 - Weight(indoor) : unit 25.0kg / panel 8.5kg
 - Sound pressure level(outdoor) : 54 dba
 - Dimension(HxWxD)(outdoor) : 695mm x 930mm x 350mm
 - Weight(outdoor) : 40.0kg
 - Pipe connection size(liquid/gas) : 9.5mm / 15.9mm

FCFG125AV1MF-RZFG125AY1M
PANEL : BCR50GMF

 - Cooling capacity : 42000 btu/h / 12.31 k/w
 - Power : 4215w
 - Sound pressure level(h/l) : 48 dba / 43 dba
 - Dimension(HxWxD)(indoor) : 288mm x 840mm x 840mm / panel 135mm x 962mm x 962mm
 - Weight(indoor) : unit 25.0kg / panel 8.5kg
 - Sound pressure level(outdoor) : 54 dba
 - Dimension(HxWxD)(outdoor) : 990mm x 940mm x 320mm
 - Weight(outdoor) : 62.0kg
 - Pipe connection size(liquid/gas) : 9.5mm / 15.9mm

FCFG140AV1MF-RZFG140AY1M
PANEL : BCR50GMF

 - Cooling capacity : 48000 btu/h / 14.07 k/w
 - Power : 5455w
 - Sound pressure level(h/l) : 48 dba / 43 dba
 - Dimension(HxWxD)(indoor) : 288mm x 840mm x 840mm / panel 135mm x 962mm x 962mm
 - Weight(indoor) : unit 25.0kg / panel 8.5kg
 - Sound pressure level(outdoor) : 56 dba
 - Dimension(HxWxD)(outdoor) : 990mm x 940mm x 320mm
 - Weight(outdoor) : 62.0kg
 - Pipe connection size(liquid/gas) : 9.5mm / 15.9mm

[ STANDARD PWP INSTALLATION) INCLUDES ]
'Within 8’ feets Copper Piping with insulation.
'Within 8’ feets 3core control wire from indoor to outdoor unit. 
'Drain Pipe UPVC 15mm x 10 feets.
'Standard MS outdoor Bracket. 
'1 Month workmanship warranty For Water Leaking and Gas Leaking.
'Testing &commissioning.

[ ADDITIONAL COPPER PIPE CHARGES ]
' If you need to place the outdoor unit a bit far from the indoor unit, the additional cost for copper pipe with wire which is more than 8’ feets  as below :
2.0 HP      RM 24.00/ft
2.5 HP      RM 26.00/ft
3.0 HP      RM 28.00/ft     

[ OPTIONAL MATERIAL]
====================================
'Power Point wiring from DB switch board RM250-RM380.00/depend distance and on site condition


- Add 15mm x 10 feets  PVC drain pipe with insulation. RM  15.00/pcs(10 feets).

- Add 2”x 3”  PVC trunking for covered copper pipe.RM  60.00/pcs(6 feets).

[ Old Unit Dismantling Service ]
- If there is a old or defective air cond need to be dismantled first, before install the new cassette air cond unit, the dismantling service charge is RM150.(Cassette type)

 ' Product Policy
Guaranteed New and Authentic unit.Customers should be aware that there will be No exchange of unit should there is any dented, malfunction. Nevertheless, manufacturer warranty claim is provided should the unit is malfunction.

More detail about METRO COOL AIR CONDITIONING SDN BHD
METRO COOL AIR CONDITIONING SDN BHD
METRO COOL AIR CONDITIONING SDN BHD Aircond Shop Selangor, VRV System Malaysia, Residential & Commercial Aircond System KL ~ METRO COOL AIR CONDITIONING SDN BHD
Contact Us flagMalaysia