Genie G Water System

Genie G Water System

Category: Type Ⅰ Ultrapure Water Systems Available
For more information, visit our official website at sciencegates.com

Description

Genie G Ultrapure & EDI Water System produces ultrapure water (Type I water) and EDI water (Type II water) from tap water directly. It offers desired solutions for research professionals who work with varieties of applications utilizing Type I ultrapure and Type II pure water in the lab. Quality of ultrapure water and EDI water meet or exceed ASTM, CLSI, CAP, and ISO Type I water and Type II water standards, respectively.

The system is CE/RoHS certified. RephiLe provides full documents support to meet user’s GMP, GSP, GAP, GCP, GLP requirements.


Specifications

Feed Water Requirements
Tap water Municipal water, Conductivity < 2000 μS/cm (1000 ppm)
Operating temperature 5 - 35 ℃
Feed water pressure 1 - 6 bar (15 - 90 psi)
Water Flow Rate
EDI water production rate (@ 25°C) 5, 10, 15 L/hr
EDI water dispensing rate Up to 2.0 L/min
Ultrapure water dispensing rate Up to 2.0 L/min
Product Water Quality
RO rejection 97 to 98% ionic rejection (new RO cartridge)
> 99% organic rejection
> 99% particulates & bacteria rejection
EDI water resistivity (@ 25°C) > 5 MΩ·cm (typically 10 - 16 MΩ·cm)
EDI water TOC* < 30 ppb
Ultrapure water resistivity (@ 25°C) 18.2 MΩ·cm
Ultrapure water TOC* < 2 ppb
Particles in ultrapure water ( > 0.2 μm) No particles (with a 0.2 μm final filter or RephiBio filter)
Microorganisms in ultrapure water < 0.01 cfu/ml (with a 0.2 μm final filter or RephiBio filter)
Pyrogens in ultrapure water < 0.001 Eu/ml (with a RephiBio filter)
RNase in ultrapure water < 0.5 pg/ml (with a RephiBio filter)
DNase in ultrapure water <10 pg/ml (with a RephiBio filter)
Product Water Quality Stored in Tank ( for tank recirculation models )
Resistivity (@25℃) > 1 MΩ·cm (default), adjustable
Dimensions
Main system dimensions (Width × depth × height) 32 × 44 × 54 cm (12.6 × 17.3 × 21.3 in)
Dispenser dimensions (Width × depth × height) 21 × 29 × 61 cm (8.3 × 11.4 × 24.0 in)
Weight 20 kg
Input Voltage 110 - 240 VAC
Operating Voltage 24 VDC
Main system power < 200 W

*In the appropriate operating conditions, otherwise typically ≤5 ppb.

 

Features:

Design & Functions
•  The system can be linked to multiple dispensers via CAN cable or wireless. “1+N” Mode.
•  Automatic temperature compensation allows RO production rate stable over a wide range of temperature.
•  Exceptionally consistent and predictable high purity Type II water from the best-in-class EDI (electrodeionization) module.
•  Fully automated system has cleaning, rising, flush and many other functions.
•  System automatically rinses a new RO membrane. Users do not need to set special rinse program for a new RO membrane.
•  A bypath automatically sends the RO water to the drain if it does not meet a preset quality standard. The RO drain water is reused to increase the water yield thus it is more environmentally friendly.
•  The main system can be tucked away to save precious bench space since it fits well to be wall-mounted, set on the shelf or under the sink.
•  The chlorine cleaning and pH cleaning functions keep the maintenance easier and ensure optimal water quality.
•  Leak protector incorporated can prevent damage from a water leakage by shutting the feed water off in case of unexpected leaking.
•  Tank recirculation model guarantees water quality in the tank.

Effective TOC level controlment
•  Built-in 254 nm lamp kills bacteria and a 185/254 nm dual wavelength UV lamp reduces TOC level in ultrapure water.
•  A tank sanitization module is equipped to effectively keep microbial growth at a lower level by LED UV light.
•  On-line TOC monitor based on complete oxidation methods.

Easy Operation and Maintenance
•  Performance history, alarms and alerts information, maintenance data of consumables as well as key parts are logged and traceable from a simple RFID scan at installation.
•  RFID tags ensure perfect placement of consumables and trace their performance.
•  Water quality, operation parameters, the status of the system, dispensers, components, and peripheral devices are stored and displayed on the large color touch screen monitor.
•  Signature verification for maintenance and service.


Cartridges and Parts

1. EDI module
•  Internal EDI module removes the remaining ions, further reduces the content of organic compounds and has a certain capacity to prevent the growth of bacteria from RO water.
•  Ion exchange resins are continuously regenerated by an electric field. No hazardous chemical regeneration or costly resin replacement is needed.
•  EDI module has a high degree of automation and minimal electricity consumption by using the equivalent of the energy.
2. Cartridge
•  Internal P Pack cartridge removes oxidants, organics, particles and scaling ions to prevent them from fouling the RO membranes and the EDI module.
•  AC Pack contains special activated carbon to remove organic impurities and free chlorines.
•  Ultra purification cartridge is filled with LeFilTM and OrganeFilTM media to remove trace ions and organics.
3. Control console
•  8-inch console controls system and peripheral devices (Such as leak protector and tank sanitization module). All operations can be done on the console by touching the screen.
•  The control console can be placed on the bench or inside a drawer for further flexibility and space saving.
•  The console screen and dispenser screens are water drop proof. You can operate the console and dispenser with latex gloves on.
•  The system has two level password protection on display menu for safety purposes.
4. Dispenser
•  The volumetric function can automatically deliver the water volume you need once it is set up.
•  With the adjusting button on a control console or a dispenser, you can dispense water at the flow rate you need up to 2 liters per minute.
•  A dispenser handle can be set on the dispenser stand, on the main system, or even hanging onto other places to free up maximum bench space.
5. Final Filter
•  A wide range of final filters (optional) is applicable to ensure ultrapure water without particles, bacteria or pyrogen.
6. Level sensor
•  The tank integrated continuous level sensor measures water level within the tank and manages the system to start or stop producing water automatically based on requirements.
•  Water level and quality inside the tank can be viewed from the control console.


Main Applications

Ultrapure Water
Important and critical applications
•  HPLC mobile phase preparation
•  Preparation of reagent blank solution
•  As sample diluents for GC, HPLC, UPLC, AA, ICP-MS and other analytical techniques
•  Preparation of buffer and culture media for mammalian cell culture
•  Preparation of molecular biology reagents, etc.

EDI Pure Water
Routine and non-critical applications
•  Preparation of chemical bio-reagents
•  Preparation of culture media
•  Preparation of solution for chemical analysis such as HPLC and ICP
•  Feed water to ultrapure water systems
•  Feed water to medical device and equipment (clinical analyzers, Aging testers etc.)
•  For serum and blood fractionation
•  For ophthalmic
 

Order Information

•  Genie G 5 Water System (RG0G005T0)
•  Genie G 10 Water System (RG0G010T0)
•  Genie G 15 Water System (RG0G015T0)

 