H3C S10500 Series Switches
The H3C S10500 switch series is designed for the data center cloud networks, next-generation enterprise core networks, and MAN convergence. It uses H3C's proprietary operating system Comware V5 and V7 and provides the following features:
Item |
S10504 |
S10506 |
S10508 |
S10508-V |
S10510 |
S10512 |
|||||
Switching capacity |
17.28Tbps/ |
20.74Tbps/ |
27.65Tbps/ |
27.65Tbps/ |
34.56Tbps/ |
41.47Tbps/ |
|||||
Forwarding capacity |
3360Mpps/ |
5040Mpps/ |
6720Mpps/ |
6720Mpps/ |
8400Mpps/ |
10080Mpps/ |
|||||
MPU slots |
2 |
2 |
2 |
2 |
2 |
2 |
|||||
LPU slots |
4 |
6 |
8 |
8(Vertical) |
10 |
12 |
|||||
Switching fabric module slots |
4 |
||||||||||
Redundancy |
Redundant MPUs, switching fabric modules, power modules, and fan trays |
||||||||||
Ethernet |
IEEE 802.1Q DLDP LLDP Static MAC configuration Limited MAC learning Port mirroring and traffic mirroring Port aggregation, port isolation, and port mirroring IEEE 802.1D (STP)/802.1w (RSTP)/802.1s (MSTP) IEEE 802.3ad (dynamic link aggregation), static port aggregation, and multi-chassis link aggregation |
||||||||||
Routing |
Static routing, RIP, OSPF, IS-IS, and BGP4 IPv4/IPv6 ECMP VRRP IPv4/IPv6 Policy-based routing IPv4/IPv6 Routing policy IPv4/IPv6 dual stack IPv6 static routing, RIPng, OSPFv3, IS-ISv6, and BGP4+ VRRPv3 Pingv6, Tenetv6, FTPv6, TFTPv6, DNSv6, and ICMPv6 IPv4-to-IPv6 transition technologies, such as IPv6 manual tunnel, 6to4 tunnel, ISATAP tunnel, GRE tunnel, and auto IPv4-compatible IPv6 tunnel |
||||||||||
Multicast |
PIM-DM, PIM-SM, PIM-SSM, MSDP, MBGP, and Any-RP IGMP V1/V2/V3 and IGMP V1/V2/V3 snooping PIM6-DM, PIM6-SM, and PIM6-SSM MLD V1/V2 and MLD V1/V2 snooping Multicast policies and Multicast QoS |
||||||||||
ACL/QoS |
Standard and extended ACLs Ingress and egress ACLs VLAN ACLs Global ACLs Diff-Serv QoS SP, WRR, SP+WRR Traffic shaping Congestion avoidance Priority marking and remarking 802.1p, TOS, DSCP, and EXP priority mapping H-QoS |
||||||||||
SDN/ OPENFLOW |
OpenFlow 1.3 Multiple controllers (EQUAL, master/slave) Multiple tables flow Group table Meter |
||||||||||
VXLAN |
VXLAN L2 switching VXLAN VTEP IS-IS+ENDP distributed control plane OpenFlow+Netconf centralized control plane |
||||||||||
MPLS/VPLS |
L3 MPLS VPN L2 VPN: VLL (Martini, Kompella) MCE MPLS OAM VPLS, VLL Hierarchy VPLS, QinQ+VPLS P/PE function LDP |
||||||||||
Security |
Hierarchical user management and password protection EAD Portal authentication MAC authentication IEEE 802.1x and IEEE 802.1x SERVER AAA/Radius HWTACACS SSHv1.5/SSHv2 Basic and advanced ACLs for packet filtering OSPF, RIPv2, BGPv4 pain text and MD5 authentication IP address, VLAN ID, MAC address multiple binding combination uRPF Active/standby data backup |
||||||||||
System mgmt |
Loading and upgrading through XModem/FTP/TFTP SNMP v1/v2/v3 sFlow, NetStream RMON and groups 1, 2, 3 and 9 NTP clocks Fault alarm and automatic fault recovery System logs Device status monitoring mechanism, including the CPU engine, backplane, chips and other key components |
||||||||||
HA |
Independent switching fabric modules 1+1 redundancy for key components such as MPUs and M+N redundancy for power modules N+1 redundancy for switching fabric modules Passive backplane Hot swapping for all components Real-time data backup on active/standby MPUs Hot patching NSR/GR for OSFP/BGP/IS-IS/RSVP Port aggregation and multi-card link aggregation BFD for VRRP/BGP/IS-IS/OSPF/RSVP/static routing, with a failover detection time less than 50 milliseconds Ethernet OAM (802.1ag and 802.3ah) RPR/RRPP DLDP VCT Smart-Link ISSU |
||||||||||
Green |
EEE(802.3az) |
||||||||||
Operating environment |
Temperature: 0°C to 45°C (32°F to 113°F) Humidity: 10% to 95% (non-condensing) |
||||||||||
Input voltage |
100~240V AC; 50/60Hz; 16A |
||||||||||
Dimension (H x W x D)/mm |
353x440x660 |
353x440x660 |
620x440x660 |
886x440x660 |
620x440x660 |
797x440x660 |
More detail about IMPACT ARROW SOLUTION SDN BHD