Chamber furnaces with air circulation are characterized particularly by their very good temperature uniformity. As a result, they are well suited for processes such as calcination and drying e.g. ceramic materials. The design as a debinding furnace for safe debinding in air or in an inert atmosphere is possible. When used for debinding in air the exhaust gases are diluted by fresh air to reliably prevent an inflammatory atmosphere in the furnace chamber. For debinding processes that have to take place under inert gas, the IDB passive safety concept with a residual oxygen content of max. 3 % is recommended.
Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions6 in mm | Heating | Electrical | Weight | Heat-up time5 | Cool-down time5 from Tmax | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
power in kW3 | to Tmax | to 150 °C in minues | ||||||||||||
°C | w | d | h | in l | W | D | H | NA/NA .. LS | connection | in kg | in minutes | Flaps4 | Fan cooling4 | |
NA 120/45(LS) | 450 | 450 | 600 | 450 | 120 | 1250 | 1550 | 1550 | 9.0 / 18.0 | 3-phase | 460 | 60 | 240 | 30 |
NA 250/45(LS) | 450 | 600 | 750 | 600 | 250 | 1350 | 1650 | 1725 | 12.0 / 24.0 | 3-phase | 590 | 60 | 120 | 30 |
NA 500/45(LS) | 450 | 750 | 1000 | 750 | 500 | 1550 | 1900 | 1820 | 18.0 / 24.0 | 3-phase | 750 | 60 | 240 | 30 |
NA 15/651 | 650 | 295 | 340 | 170 | 15 | 470 | 790 | 460 | 2.8 | 1-phase | 60 | 40 | - | - |
NA 60/65 | 650 | 350 | 500 | 350 | 60 | 910 | 1390 | 1475 | 9.0 | 3-phase | 350 | 120 | 270 | 60 |
NA 120/65 | 650 | 450 | 600 | 450 | 120 | 990 | 1470 | 1550 | 12.0 | 3-phase | 460 | 60 | 300 | 60 |
NA 250/65 | 650 | 600 | 750 | 600 | 250 | 1170 | 1650 | 1680 | 20.0 | 3-phase | 590 | 90 | 270 | 60 |
NA 500/65 | 650 | 750 | 1000 | 750 | 500 | 1290 | 1890 | 1825 | 27.0 | 3-phase | 750 | 60 | 240 | 60 |
N 30/85 HA | 850 | 290 | 420 | 260 | 30 | 607 + 255 | 1175 | 1315 | 5.5 | 3-phase2 | 195 | 180 | 900 | 90 |
N 60/85 HA | 850 | 350 | 500 | 350 | 60 | 667 + 255 | 1250 | 1400 | 9.0 | 3-phase | 240 | 150 | 900 | 120 |
N 120/85 HA | 850 | 450 | 600 | 450 | 120 | 767 + 255 | 1350 | 1500 | 13.0 | 3-phase | 310 | 150 | 900 | 120 |
N 250/85 HA | 850 | 600 | 750 | 600 | 250 | 1002 + 255 | 1636 | 1860 | 20.0 | 3-phase | 610 | 180 | 900 | 180 |
N 500/85 HA | 850 | 750 | 1000 | 750 | 500 | 1152 + 255 | 1886 | 2010 | 30.0 | 3-phase | 1030 | 180 | 900 | 210 |
N 675/85 HA | 850 | 750 | 1200 | 750 | 675 | 1152 + 255 | 2100 | 2010 | 30.0 | 3-phase | 1350 | 210 | 900 | 210 |
1Table-top model 2Heating only between two phases 3Depending on furnace design connected load might be higher 4Additional equipment 5Empty furnace 6External dimensions vary when furnace is equipped with additional equipment. Dimensions on request. |