Description
H2 Version for Operation with Hydrogen or other Reaction Gases
In the H2 version the retort furnaces can be operated under hydrogen or other reaction gases. For these applications, the systems are additionally equipped with the required safety technology. Only certified and industry proven safety sensors are used. The retort furnaces are controlled by a fail-safe PLC control system (S7-300F/safety controller).
- Certified safety concept
- Automation package
- Redundant gas inlet valves for hydrogen
- Monitored pre-pressures of all process gases
- Bypass for safe purging of furnace chamber with inert gas
- Pressure-monitored emergency flooding with automated solenoid valve opening
- Electric or gas-heated exhaust gas torch for H2 post-combustion
- Atmospheric operation: H2-purging of retort starting from room temperature at controlled over pressure (50 mbar relative)
Additional equipment
- Partial pressure operation: H2 flushing at underpressure in the retort starting from 750 °C furnace chamber temperature
- Inner process hood in the retort for debinding under hydrogen
- Process control and documentation via Nabertherm Control Center (NCC) for monitoring, documentation and control
More detail about Obsnap Instruments Sdn. Bhd.