Features:
pH:
*Multiparameter water quality meter is equipped with a 6.5 inches backlit LCD display 1 to 5 points calibration with automatic recognition for USA, NIST and DIN buffers.
*Automatic electrode diagnosis shows the pH slope and offset.
ORP:
*1 point offset calibration allows adjusting the displayed value to a known standard.
*Relative and absolute millivolt modes ensure the reliable ORP measurements.
Ion Concentration:
*2 to 5 points calibration, including the 8 concentration points can be selected.
*Direct ion concentration readout simplifies the measurement process.
*Automatic electrode diagnosis shows the calibration points and slopes.
*Selectable concentration units (ppm, mg/L, mol/L, mmol/L) and ionic valency.
Conductivity/TDS/Salinity/Resistivity:
*1 to 5 points calibration with automatic recognition for conductivity standards.
*Selectable cell constant, reference temperature, TDS factor, linear and pure water compensations, seawater and practical salinity measurement modes.
*Automatic electrode diagnosis shows the calibration points and factors.
Dissolved Oxygen:
*1 or 2 points calibration using the air-saturated water or zero oxygen solution
*Salinity and barometric pressure compensations eliminate the measurement error
Other Features:
*Automatic temperature compensation ensures accurate readings over the entire range.
*Auto-Read function senses and locks the measurement endpoint.
*Calibration due alarm prompts user to calibrate the meter regularly.
*Setup menu allows setting the number of calibration points, resolution, stability criteria,temperature unit,
date and time, etc.
*Reset function automatically resumes all settings back to the factory defaults.
*Expanded memory stores or recalls up to 500 data sets.
*USB communication interface for data transfer and timed interval readings.
Technical Parameters:
Model |
PH-900 |
|
pH |
Range |
-2.000~20.000pH |
Resolution |
0.001, 0.01,0.1 pH, selectable |
|
Accuracy |
±0.002pH |
|
Calibration Points |
1 to 5 points |
|
pH Buffer Options |
USA, NIST, DIN, 2 custom buffers |
|
ORP(optional) |
Range |
±1999.9mV |
Resolution |
0.1,1mV, selectable |
|
Accuracy |
±0.2mV |
|
Calibration Points |
1 point |
|
lon(optional) |
Range |
0.001-19999 (depending on the range of ISE) |
Resolution |
0.001, 0.01,0.1, 1 |
|
Accuracy |
±0.5% F.S. (monovalent),±1%F.S. (divalent) |
|
Measurement Units |
ppm, mg/L, mol/L, mmol/L |
|
Calibration Points |
2 to 5 points (0.001, 0.01,0.1, 1,10, 100, 1000, 10000) |
|
Conductivity |
Range |
0.1 ~2pS/cm(CON-0.1 .optional); 2-20mS/cm(CON-1 .standard); 20~200mS/cm(CON-10,optional) |
Resolution |
0.001,0.01,0.1, 1 |
|
Accuracy |
±0.5% F.S. |
|
Calibration Points |
1 to 5 points |
|
Calibration Solutions |
10pS/cm, 84pS/cm, 1413pS/cm, 12.88mS/cm, 111.8mS/cm |
|
Temperature Coefficient |
Linear (0.0~10.0%/°C), pure water |
|
Reference Temperature |
20/25P |
|
Cell Constant |
K=0.1,1,10 or custom |
|
TDS |
Range |
0-10.00, 100.0, 1000ppm, 10.00, 200.0ppt |
Resolution |
0.01,0.1,1 |
|
Accuracy |
±1%F.S. |
|
TDS Factor |
0.1-1.0 (default 0.5) |
|
Salinity |
Range |
0.00~42.00psu, 0.00~80.00ppt |
Resolution |
0.01 |
|
Accuracy |
±1%F.S. |
|
Resistivity |
Range |
0.00-20.00MQ |
Resolution |
0.01 |
|
Accuracy |
±1%F.S. |
|
DO |
Range |
0.00-20.OOmg/L, 0.0*200.0% saturation |
Resolution |
0.01 mg/L, 0.1% |
|
Accuracy |
±0.2mg/L, ±2.0% |
|
Calibration Points |
1 or 2 points |
|
Barometric Pressure Correction |
60.0-112.5kPa/450-850mmHg, manual |
|
Salinity Correction |
0.0~50.0g/L, manual |
|
Other Specifications |
Temperature Compensation |
0~100°C/32~212°F, manual or automatic |
Memory |
500 data sets, USB communication interface |
|
Power Requirements |
DC5V power adapter |
|
Dimension |
210*188*60mm |
|
Net Weight |
1.5kg |
|
Packing Size |
300*250*200mm |
|
Gross Weight |
1.7kg |