HI6321 is a streamlined Conductivity/Resistivity/TDS/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module.
HI6321 is a streamlined Conductivity/Resistivity/TDS/Salinity/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module.
Compact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity/ resistivity/TDS/salinity probe.
Recommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms:
The result is reliable electrolytic conductivity (EC), TDS (Total Dissolved Solids), resistivity, or Seawater Salinity in percent, psu, or ppt units.
TDS is a calculated value based on the conductivity of the solution (TDS = factor x EC25). A TDS factor is a conversion factor used to change an EC measurement to a ppm measurement.
Sal psu: The practical salinity of seawater relates the ratio of electrical conductivity of a normal seawater sample at 15 °C and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g/Kg water at the same temperature and pressure. Under these conditions the ratio is equal to 1 and S=35. The practical salinity scale may be applied to values 0 through 42.00 psu at temperatures between 0 to 35 °C.
Sal ppt: measurements expressed in ppt are based on the Natural Seawater Scale that extends from 0.00 to 80.00 g/L and covers 10 to 31 °C temperature range. It determines the salinity based upon a conductivity ratio of sample to standard seawater at 15 °C and an approximate salinity value of 35 in seawater.
Sal %: in this scale 100% salinity is equivalent to roughly 10% solids.
SKU | HI6321 |
---|---|
Product Name | Advanced Conductivity Benchtop Meter - HI6321 |
Quote Required | Yes |
Conductivity Range | 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm |
Conductivity Resolution | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
Conductivity Accuracy | ±1 % of reading (±0.01 μS/cm) |
Resistivity Range | 1.0 to 99.9 Ω·cm; 100 to 999 Ω·cm; 1.00 to 9.99 KΩ·cm; 10.0 to 99.9 KΩ·cm; 100 to 999 KΩ·cm; 1.00 to 9.99 MΩ·cm; 10.0 to 100.0 MΩ·cm |
Resistivity Resolution | 0.1 Ω·cm; 1 Ω·cm; 0.01 KΩ·cm; 0.1 KΩ·cm; 1 KΩ·cm; 0.01 MΩ·cm; 0.1 MΩ·cm |
Resistivity Accuracy | ±1 % of reading (±1 Ω·cm) |
Total Dissolved Solids (TDS) Range | 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) |
Total Dissolved Solids (TDS) Resolution | 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt |
Total Dissolved Solids (TDS) Accuracy | ±1 % of reading (±0.01 ppm) |
Salinity Range | 0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale |
Salinity Resolution | 0.01 for Practical Scale / Natural Sea Water 0.1 % for Percent Scale |
Salinity Accuracy | ±1 % of reading |
Temperature Range | −20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K |
Temperature Resolution | 0.1 °C; 0.1 °F; 0.1 K |
Temperature Accuracy | ±0.2 °C; ±0.4 °F; ±0.2 K |
Conductivity Calibration points | Auto standard recognition / User standard, Single Point / Multi Point calibration |
Conductivity Calibration Standard solutions | 84.00 µS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm |
Conductivity Calibration Reminder | Disabled Daily |
Salinity Calibration | 1 point for Percent Scale |
Temperature Compensation | Automatic or Manual |
Reading Modes | Direct Direct/Autohold |
Reading Stability criteria | Accurate Medium Fast |
Reading Sampling | rate 1000 ms |
EC Views Basic | Measurement (EC, Resistivity, TDS, Salinity, Temperature) Stability status |
EC Views Simple GLP | Basic view information Last calibration date, offset |
EC Views Full GLP | Simple GLP information and calibration point details |
EC Views Table | Measurements updated every second are displayed in table |
EC Views Graph (Plot) | Measurement versus time graph can be panned or zoomed (pinch-to-zoom technology) |
Logging Type | Automatic, Manual, Autohold |
Logging Number of records | 50 000 maximum per file Stores at least 1 000 000 data points per user |
Logging Automatic interval | 1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes |
Logging Sample ID | Incremental mode |
Logging Export option | .csv file format |
Users | Up to 9 users and the default administrator account |
Connectivity USB-A | 2 ports for keyboard input or USB thumb drive |
Connectivity USB-C | 1 port for PC connectivity and USB-C type thumb drive |
Connectivity Wi-Fi & Ethernet | FTP Web server Log transfer and download Email |
Connectivity RS232 | Connecting peripherals |
Power supply | DC adapter 100-240AC to 24VDC 2.5A |
Environment | 0 - 50 °C / 32 - 122 °F / 273 - 323 K maximum 95% RH non-condensing |
Dimensions | 205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “) |
Weight | Approximately 1.2 kg (26.5 lbs.) |