Specifications:
Item | Specifications | ||
Operating ambient temperature and humidity | 0 to 40°C 20% to 90% (with no condensation) |
||
Storage ambient temperature and humidity | -20 to 65°C 20% to 90% (with no condensation) |
||
Operating and storage atmosphere | No corrosive gases | ||
Vibration resistance *1 | Acceleration of 49 m/s2 *2 24.5 m/s2 max. in X, Y, and Z directions when the motor is stopped |
||
Impact resistance | Acceleration of 98 m/s2 max. 3 times each in X, Y, and Z directions | ||
Insulation resistance | Between power terminals and FG terminals: 10 MW min. (at 500 VDC Megger) | ||
Dielectric strength | Between power terminals and FG terminals: 1,500 VAC for 1 min (voltage 100 V, 200 V) Between power terminals and FG terminals: 1,800 VAC for 1 min (voltage 400 V) Between brake terminal and FG terminals: 1,000 VAC for 1 min | ||
Insulation class | Class F | ||
Protective structure | IP67 (except for the through-shaft part and connector pins) IP20 if you use a 30-meter or longer encoder cable. | ||
International standard | EU Directives and UK legislation |
Low Voltage | EN 60034-1/-5 |
UL standards | UL 1004-1/-6 | ||
CSA standards | CSA C22.2 No.100 (with cUR mark) |