The Ramsey™ Conveyor Protection Switches Feature:
Thermo Scientific Ramsey Belt Position Limit Switches
It ‘ consists of a external lever equipped with one contact wheel to be operate by the controlled machine. The position of external lever on the shaft may be changed as required, thus allowing the mounting of the housing on an horizontal, vertical or any inclined plate. The unit is equipped with N°2 microswitches operate at a 18° +/- 2° inclination of the external lever. Each microswitch is provide of: N°1 (NC) contact + N°1 (NO) contact.
Limit Switch Mod. 60-32G.
• Check gasket integrity
• Check operation of switches
• Check wheel rotation of contact
ATEX: Additional information for maintenance The maintenance of installed products in hazardous areas with danger of explosion requires special attention, especially those aspects that could affect the proper functioning of the machine or be due to source of ignition is not provided. In addition to the general guidelines below, please follow the information contained in the standard “Verification and maintenance of electrical installations in hazardous areas with explosion” IEC 60079-17.