Professional meter for photovoltaic installations up to 1500 V
The PVM-1530 is a pioneering meter for photovoltaic installations up to 1500 V with such a substantial number of measurement functions. It can be used for category 1 measurements according to IEC 62446-1. It allows the measurement of the I-U curve for category 2 according to IEC 62446-1. Furthermore, it also converts measured parameters into STC conditions according to IEC 60891. Comprehensive, yet simple to use, it flawlessly performs its tasks in monitoring the safety and efficiency parameters of photovoltaic (PV) installations.
Features
Measured parameters
Cat. 1 measurements and I-U characteristics
The PVM-1530 is a pioneering meter for photovoltaic installations up to 1500 V with such a substantial number of measurement functions. Their selection is done via a touch screen. The screen is large, colorful and with strong backlight so that operation in full sunlight is not a problem. Extensive structural memory significantly reduces the time for preparing post-measurement documentation.
Tightness and durability
Light meters perform well in harsh environmental conditions. The PVM-1530’s housing is rugged and tight when closed to easily ensure that the meter is protected during measurement.
Communication and software
Measurement data from the PVM-1530 can be transferred to a computer via cable or wireless communication. Saving the downloaded data to popular formats and printing is ensured by Sonel Reader. In order to generate a report on electric shock protection use the optional software: Sonel Reports Plus.
Trouble? reSYNC!
It may happen that in the course of measurements the PVM-1530 moves away from the IRM-1 so far, that communication between them is lost. If the measurements are continued, then after the connection is restored, the results will be automatically supplemented with environmental parameters, which in the meantime were recorded by the IRM-1 in its temporary memory, and converted into STC conditions.
Specifications
Parameter | Measurement range | Display range | Resolution | Accuracy |
---|---|---|---|---|
Voltage | ||||
AC voltage | 0.0 V…1000.0 V | 0.0 V…1000.0 V | 0.1 V | ±(2% m.v. + 6 digits) |
DC voltage | 0.0 V…1500.0 V | 0.0 V…1500.0 V | 0.1 V | ±(0.5% m.v. + 2 digits) |
Frequency | 10.0 Hz…100.0 Hz | 0 Hz…100.0 Hz | 0.1 Hz | ±(0.5% m.v. + 2 digits) |
Short circuit current ISC | ||||
Voltage 1500 V DC | 0.00…30.00 A | 0.00…30.00 A | 0.01 A | ±(1% m.v. + 2 digits) |
Voltage 1000 V DC | 0.00…40.00 A | 0.00…40.00 A | 0.01 A | ±(1% m.v. + 2 digits) |
Insulation resistance | ||||
Insulation resistance at AC side | ||||
• Measuring voltage 250 V | 250 kΩ…200 MΩ acc. to IEC 61557-2 |
0.0 kΩ…200.0 MΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
• Measuring voltage 500 V | 500 kΩ…500 MΩ acc. to IEC 61557-2 |
0.0 kΩ…500.0 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
• Measuring voltage 1000 V | 1000 kΩ…1.000 GΩ acc. to IEC 61557-2 |
0.0 kΩ…1.000 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
Insulation resistance at DC side | ||||
• Measuring voltage 250 V / 500 V / 1000 V / 1500 V | 250 kΩ…500 GΩ acc. to IEC 61557-2 |
0.0 kΩ…500.0 GΩ | from 0.1 kΩ | ±(8% m.v. + 8 digits) |
Resistance of protective conductors and equipotential bondings | ||||
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current | 0.10 Ω…1999 Ω acc. to IEC 61557-4 |
0.00 Ω…1999 Ω | from 0.01 Ω | from ±(2% m.v. + 3 digits) |
Operating current | as for CMP-1015-PV | as for CMP-1015-PV | as for CMP-1015-PV | as for CMP-1015-PV |
Power measurement | 0.0 kW…999.0 kW | 0.0 kW…999.0 kW | 0.1 kW | ±(6% m.v. + 5 digits) |
"m.v." – measured value