SENTRON PAC3220 LCD 96X96 mm Power Monitoring Device Controll panel instrument for electrical values protocol: Modbus TCP with graphics display U rated input: 690/400V 45-65Hz IE rated input: X/1A oder X/5A AC Power supply: 100 ... 250 V +-10 % AC/DC screw connections
Model | ||
product brand name | SENTRON | |
product designation | multimeter | |
design of the product | basic | |
product type designation | 7KM PAC3220 | |
Measurements | ||
measuring procedure | ||
● for voltage measurement | TRMS | |
● for current measurement | TRMS | |
type of measured value detection | complete | |
voltage curve | Sinusoidal or distorted | |
measurable line frequency | ||
● initial value | 45 Hz | |
● full-scale value | 65 Hz | |
operating mode for measured value detection automatic line frequency detection | Yes | |
operating mode for measured value detection | ||
● set at 50 Hz | No | |
● set to 60 Hz | No | |
Supply voltage | ||
design of the power supply | Wide-range power supply | |
type of voltage of the supply voltage | AC/DC | |
supply voltage at AC | 100 ... 250 V | |
supply voltage at DC | 100 ... 250 V | |
Degree of protection protection class | ||
protection class IP on the front | IP65 | |
Suitability | ||
suitability for operation | Installation in stationary panels in closed rooms | |
Product Functions | ||
product function | ||
● voltage measurement | Yes | |
● current measurement | Yes | |
● active power measurement | Yes | |
● reactive power measurement | Yes | |
● frequency measurement | Yes | |
Display and operation | ||
design of the display | LCD | |
height of the display | 54 mm | |
width of the display | 72 mm | |
color of the background of the display | white | |
illuminance of display backlight adjustable | No | |
time-controlled reduction of the illuminance of display backlight possible | Yes | |
display contrast adjustable | Yes | |
national language on the display screen is supported | de, en, fr, spa, ita, por, tur, chi, pol | |
number of keys | 4 | |
Communication | ||
transfer rate minimum | 10 000 kbit/s | |
transfer rate maximum | 100 000 kbit/s | |
number of interfaces according to Fast Ethernet | 2 | |
type of electrical connection of the fast Ethernet interface | 2 x RJ45 | |
protocol at the Ethernet interface is supported | MODBUS TCP | |
Fault limits | ||
reference condition for metering accuracy | In accordance with IEC61557-12, IEC62053-22 and IEC62053-23 | |
formula for relative total measurement inaccuracy | ||
● for measured variable voltage | +/- 0.2 % | |
● for measured variable current | +/- 0.2 % | |
● for measured variable active power | +/- 0.5 % | |
● for measured variable reactive power | +/- 1 % | |
● for measured variable output factor | +/- 0,5 % | |
● for measured variable active energy | Cl. 0.5 acc. to... IEC62053-22 | |
● for measured variable reactive energy | Class 2 according to IEC61557-12 and/or IEC62053-23 | |
Inputs Outputs | ||
number of digital inputs | 2 | |
type of electrical connection at the digital inputs | screw-type terminals | |
operating conditions for digital inputs external voltage supply | Yes | |
input voltage at digital input at DC maximum | 30 V | |
input current at digital input | ||
● initial value for signal<1>-recognition | 7 mA | |
number of digital outputs | 2 | |
type of switching output | bidirectional | |
digital output version | switching or pulse output function | |
operating voltage as output voltage at DC maximum permissible | 30 V | |
type of electrical connection at the digital outputs | screw-type terminals | |
output current | ||
● at the digital outputs at DC limited to 100 ms maximum | 130 mA | |
internal resistance at the digital outputs | 55 !& | |
standard for pulse emitter | according to IEC62053-31 | |
pulse duration | ||
● initial value | 30 ms | |
● full-scale value | 500 ms | |
adjustable time period minimum | 10 ms | |
switching frequency at digital output maximum | 17 Hz | |
property of the output short-circuit proof | Yes | |
Measuring inputs | ||
measurable supply voltage between (PE)N and L at AC maximum rated value | 400 V | |
measurable supply voltage between (PE)N and L at AC | ||
● minimum | 11.5 V | |
● maximum | 480 V | |
measurable supply voltage between the line conductors at AC maximum rated value | 690 V | |
voltage measuring range extension with external voltage transformers | yes | |
line conductors and neutral conductors internal resistance for voltage measurement | 1.5 M!& | |
measuring category for voltage measurement | CAT III | |
measurable current | ||
● 1 at AC rated value | 1 A | |
● 2 at AC rated value | 5 A | |
relative measurable current at AC | ||
● minimum | 1 % | |
● maximum | 100 % | |
current measuring range extension with external current transformers | Yes | |
zero point suppression for current measurement | 0 ... 10 % | |
apparent power consumption for current measurement | ||
● with measuring range 5 A per phase | 0.3 VA | |
measuring category for current measurement | CATIII | |
Connections | ||
type of electrical connection | ||
● at the measurement inputs for voltage | screw-type terminals | |
● at the measurement inputs for current | screw-type terminals | |
Mechanical Design | ||
fastening method standard rail mounting | No | |
size of Power Monitoring Device | size 96 | |
height | 96 mm | |
width | 96 mm | |
depth | 56 mm | |
installation depth | 51 mm | |
net weight | 325 g | |
mounting position | vertical | |
Environmental conditions | ||
ambient temperature during operation | ||
● minimum | -25 °C | |
● maximum | 55 °C | |
ambient temperature during storage | ||
● minimum | -25 °C | |
● maximum | 70 °C | |
relative humidity at 25 °C without condensation during operation maximum | 75 % | |
installation altitude at height above sea level maximum | 2 000 m | |
degree of pollution | 2 | |
Certificates | ||
certificate of suitability as EC Declaration of Conformity | yes |