● Closed loop with inverter control system to keep the stability and accuracy of the conveyor speed
● The assistant pressure device nearby the entrance to prevent the PCB from slipping
● Spray nozzle driving by stepping motor is to make sure the coating uniformly
● Module design of spray fluxer system and the design of nozzle always be perpendicular to rail,which can make sure the flux penetrates PCB easily
● Forced air cooling system to attain the cold-down slope as per lead-free required
● Conveyor angle is adjustable by manual
● Standard with hot air heating for preheating zones
● Module design suitable for SMT & THT component soldering
● Exhaust adopt centrifugal fan with double filters to avoid any flux drop to PCB
● The level of flux container is controlled by non-contact sensors to ensure nocorrosion and longer life
● Flux spray nozzle with self-cleaning system
● Standard with air knives to prevent flux expand to preheat zone
● Wave height control adopted with inverter, it can be set individually
● 1/4HP high power mechanical pump to meet the wave as high as 15mm
● Light & Sound alarm, emergency stop and over-load protection
MODEL | ATS-350 | |
Dimension(L*W*H) mm | 4401×1582×1735mm | |
Weight | About 1800KG | |
Power Supply | 3P5W AC 380V 50/60Hz Option:3P5W AC 220V 50/60Hz | |
Operating power | ≤9KW | |
Preheating temperature rise time | ≤18min | |
Preheat temperature | Room Temperature~230℃ | |
Width range of PCB | 50-350mm | |
PCB board component height | Top 120mm,Bottom 25mm | |
PCB Converyor Direction | L→R Option:R→L | |
PCB inlet transport height | 750±20mm(Entrance) | |
Transmission Speed | 500~1800mm/min | |
Device Layout | ||
Preheat zones number | 3 Zones Option: Top Preheating(MAX 3PCS) | |
Preheat mode | Hot Air Preheating | Infrared Preheating |
Preheating temperature control mode | PID+SSR | |
Control mode | PC+PLC | |
Tin furnace capacity | Lead-free:About 480KG | |
Working mode of tin furnace | Mechanical Pump | |
Furnace liner material | Castiron + Enamel Option: All Titanium | |
Cooling mode | Forced Air Cooling | |
The above contents are subject to change without further notice! |