PDC Precision Power Distribution System

PDC Precision Power Distribution System

Category: PDC Precision Power Distribution System Available
For more information, visit our official website at swicpower.com

Description

Product Introduction

Fully smart power distribution provides high-precision measurement data to monitoring system. It collects power data in real time through a unique display module, and uploads the collected data to the host computer platform through Environmental Monitoring System. This PDC helps users to optimize network data centers, strengthen energy consumption management, improve server operating efficiency, and achieve a full range of reliable guarantees for green IDC.

We adopt a new modular design, combined with the practical needs of MDC project delivery and engineering implementation, focusing on solving the needs of system maintainability, scalability, system link, wiring, debugging, aesthetics and other aspects, suitable for most of the front-end acquisition application environment. It can also meet customers' special customized design needs.

 

Product Feature

◆ Real Time Data Collection

System adopts high efficient data processing methods, provide real-time data detection for current, voltage, power, power factor, electrical energy, and frequency. It also provide users with a basis for calculate PUE to optimize the energy consumption of the data center.

◆ Real Time Alarm function

Multi-layer alarm settings can prevent potential failures to ensure that measures are taken in failure forecast. Alarms including overload, over-voltage, under voltage, and three-phase unbalance, isolation transformer over-temperature, and lightning protection failure. Through the cooperation of the display and LAD, alarm information can be reported to the operation and maintenance personnel through display, sound and light alarm, SMS and email immediately.

◆ High precision

Provide accurate measurement data calculation to meet various needs. To meet the monitoring of rack and blade server power supplies, Hall sensors are widely used to minimize measurement errors. The branch circuit supports a maximum circuit measurement requirement of 100A.

◆ High performance and Integration

19-inch standard structure is adopted to make PDC a good performance and high integration to ensure reliability.

◆ Various Communication ports

It provides isolated RS485, Modbus data protocol, expandable SNMP card with protocol integration. System also support HTTP, NTP and other network protocols and log records.

◆ Expandable 7-inch HMI module

Comprehensively monitor the operating parameter and achieve maximum visual operation through HMI interface.

◆ Built-in SNMP-Link software 

SNMP-Link has the management of the LAN data center infrastructure. Not only can you connect and manage equipment network through SNMP protocol, but also can connect devices through Rs485 or CANBUS, Remote access and management available.

◆ Necessary DC interface

JPDC can provide two 12V/8.5A DC interfaces to meet the comprehensive use needs of users.

 

Product function

◆ Single-phase and three-phase power distribution module for selection.

◆ Provide Real-time data collection of current, voltage, power, PF, electric energy and frequency. 

◆Circuit modular design, support 8-circuit multiple expansion. 

◆ Provide temperature and humidity, dry contact sensor data acquisition. 

◆ Provide 7-inch HMI integrated interface module selection. 

◆ Fully isolated IIC, RS485 communication interface, optional SNMP card module supporting the network. 

◆ Integrated lightning protection module, integrated 12V DC module. 

◆ Provide a variety of brand circuit breaker options.

 

Product Category

By phase

◆ Single input 220V/Single output 220V Power

◆ Three phase input 380V/Single output 220V Power

◆ Three phase input 380V/Three phase output 380V Power

By capacity

◆ Single input/Single output Total input current specifications: 32A, 63A, 80A Range: Single row 1-3 cabinets

◆ Three phase input/Single output Total input current specifications: 80A, 100A, 125A Range: Single row 3-4 cabinets

◆ Three phase input/Three phase output Total input current specifications: 80A, 100A, 125A Range: Single row 4-10 cabinets

◆ Three phase input/Three phase output Total input current specifications: 160A, 250A, 450A Range: Double row within 25 cabinets

By UPS power configuration structure 

◆ N series:single UPS 

◆ 2N series: two UPS

◆ N+1 series: redundant parallel UPS

More detail about Swicpower Technology Sdn Bhd
Swicpower Technology Sdn Bhd
Swicpower Technology Sdn Bhd SCADA System Selangor, Integrated Control Systems Malaysia, E&I Manpower Supply KL ~ Swicpower Technology Sdn Bhd
Contact Us flagMalaysia