Fluke 87V MAX True-rms Digital Multimeter | Fluke 87V Industrial Multimeter | Fluke 289 True-RMS Data Logging Multimeter | Fluke 179 True-RMS Digital Multimeter | Fluke 1587 FC Insulation Multimeter | |
---|---|---|---|---|---|
CAT rating | CAT III 1000 V CAT IV 600 V |
CAT III 1000 V CAT IV 600 V |
CAT III 1000 V CAT IV 600 V |
CAT III 1000 V CAT IV 600 V |
CAT III 1000 V CAT IV 600 V |
True-rms readings | ' | ' | ' | ' | ' |
Voltage AC/DC | 1000 V | 1000 V | 1000 V | 1000 V | 1000 V |
Current AC/DC | 10 A | 10 A | 10 A | 10 A | 400 mA |
Resistance | 50 MΩ | 50 MΩ | 500 MΩ | 50 MΩ | 50 MΩ |
Capacitance | 9,999 μF | 9,999 μF | 100,000 μF | 9,999 μF | 9,999 μF |
Temperature | -200 °C to 1090 °C | -200 °C to 1090 °C | -200 °C to 1350 °C | -40 °C to 400 °C | -40 °C to 537 °C |
Additional measurement capabilities |
Conductance, continuity/diode test, duty cycle, frequency, microamps, motor drive (VFD) measurement, pulse width, elative reference |
Frequency, continuity/diode test, motor drive (VFD) measurement, duty cycle, microamps, analog bar graph, relative reference |
Conductance (50ns), duty cycle, frequency, continuity/diode test, low input impedance, microamps, pulse width |
Continuity/diode test, frequency, microamps |
Frequency, Pi/DAR timed ratio tests, continuity/diode test, motor drive (VFD) measurement, microamps, relative reference |
IP rating | IP 67 | IP 30 | IP 42 | - | - |
Battery life | 800 hours | 400 hours | 200 hours | 200 hours | 1000 hours |
Drop test | 4 meters | 3 meters | - | - | - |
Backlit keypad | Yes | No | No | No | No |
Electrical Specifications | ||
DC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 0.1 mV | |
AC Voltage | Range | 0.1 mV to 1000 V |
Accuracy | ±(0.7% + 4) true-rms | |
AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
Maximum resolution | 0.1 mV | |
DC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.1 µA | |
AC Current | Range | 0.1 μA to 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) true-rms | |
Maximum resolution | 0.1 µA | |
Resistance | Range | 0.1 Ω to 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Range | 0.01 nF to 9999 μF |
Accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Range | 0.5 Hz to 199.99 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement range | –200.0 °C to 1090 °C –328.0 °F to 1994.0 °F excluding probe |
|
80 BK temperature probe | –40.0 °C to 260 °C, ± 2.2 °C or 2% whichever is greater –40.0 °F to 500 °F, ± 4.0 °F or 2% whichever is greater |
|
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode test | Range | 2 V |
Resolution | 0.001V | |
Accuracy | ±(1% + 1) | |
Diagnostics and data storage | Peak Min/Max | 250 μS |
Min/Max/Avg | Yes | |
Reading hold/Auto (Touch) Hold | Yes | |
Relative reference | Yes | |
Display | Digital | 6000 counts updates 4/second 19,999 counts in high–resolution mode |
Analog bar graph | 32 segments, updates 40/second | |
Backlight | Two level | |
Low pass filter (VFD measurements) | Yes | |
Input Alert™ | Yes | |
Safety Specifications | ||
Safety rating | IEC61010-1: Pollution Degree 2 IEC 61010-2-033: CAT IV 600 V, CAT III 1000 V |
|
Agency approvals | CE, CSA | |
Mechanical and General Specifications | ||
IP rating | IEC 60529: IP67 | |
Power | Three AA batteries. 800 hours typical, without backlight | |
Size | 6.0 x 10.1 x 21.5 cm (with holster) | |
Weight | 698.5 g (with holster) | |
Warranty | Limited lifetime | |
Environmental Specifications | ||
Operating temperature | -15 °C to 55 °C, to -40 °C for 20 minutes when taken from 20 °C | |
Storage temperature | -40 °C to + 60 °C | |
Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
|
Operating altitude | 2000 m |