P+F KFU8-UFC-Ex1.D Frequency Converter with Trip Values

P+F KFU8-UFC-Ex1.D Frequency Converter with Trip Values

Category: Signal Converter & Signal Isolator Available
For more information, visit our official website at ecinstruments.net

Description

Frequency Converter with Trip Values KFU8-UFC-Ex1.D

< 1-channel isolated barrier
< Universal usage at different power supplies
< Input for NAMUR sensors or dry contacts
< Input frequency 1 mHz ... 5 kHz
< Current output 0/4 mA ... 20 mA
< Relay contact and transistor output
< Start-up override
< Line fault detection (LFD)
< Up to SIL 2 acc. to IEC/EN 61508 / IEC/EN 61511

Datasheet excerpt: Technical data of  KFU8-UFC-Ex1.D

General specifications
Signal type Digital Input
Functional safety related parameters
Safety Integrity Level (SIL) SIL 2
Supply
Connection terminals 23, 24
Rated voltage 20 ... 90 V DC / 48 ... 253 V AC 50 ... 60 Hz
Power dissipation/power consumption ≤ 2 W ; 2.5 VA / 2.2 W ; 3 VA
Interface
Programming interface programming socket
Input
Connection side field side
Connection Input I: intrinsically safe: terminals 1+, 3-
Input II: non-intrinsically safe: terminals 13+, 14-
Input I sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
  Pulse duration > 50 µs
  Input frequency 0.001 ... 5000 Hz
  Line fault detection breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
Input II startup override: 1 ... 1000 s, adjustable in steps of 1 s
  Active/Passive I > 4 mA (for min. 100 ms) / I < 1.5 mA
  Open circuit voltage/short-circuit current 18 V / 5 mA
Output
Connection side control side
Connection output I: terminals 10, 11, 12
output II: terminals 16, 17, 18
outout III: terminasl 19+, 20-
output IV: terminals 8+, 7-
Output I, II signal, relay
  Contact loading 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
  Mechanical life 5 x 107 switching cycles
  Energized/De-energized delay approx. 20 ms / approx. 20 ms
Output III electronic output, passive
  Contact loading 40 V DC
  Signal level 1-signal: (L+) - 2.5 V (50 mA, short-circuit/overload proof)
0-signal: switched off (off-state current ≤ 10 µA)
Output IV analog
  Current range 0 ... 20 mA or 4 ... 20 mA
  Open loop voltage max. 24 V DC
  Load max. 650 Ω
  Fault signal downscale I ≤ 3.6 mA , upscale ≥ 21.5 mA (acc. NAMUR NE43)
Transfer characteristics
Input I  
  Measuring range 0.001 ... 5000 Hz
  Resolution 0.1 % of the measurement value , ≥ 0.001 Hz
  Accuracy 0.1 % of the measurement value , > 0.001 Hz
  Measuring time < 100 ms
  Influence of ambient temperature 0.003 %/K (30 ppm)
Output I, II  
  Response delay ≤ 200 ms
Output IV  
  Resolution < 10 µA
  Accuracy < 20 µA
  Influence of ambient temperature 0.005 %/K (50 ppm)
Galvanic isolation
Input I/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output I, II/other circuits reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, III reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III/start-up override basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III/IV basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output IV/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Start-up override/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/power supply reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Interface/output III basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Indicators/settings
Display elements LEDs , display
Control elements Control panel
Configuration via operating buttons
via PACTware
Labeling space for labeling at the front
Directive conformity
Electromagnetic compatibility  
  Directive 2014/30/EU EN 61326-1:2013 (industrial locations)
Low voltage  
  Directive 2014/35/EU EN 61010-1:2010
Conformity
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529:2001
Input EN 60947-5-6:2000
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Mechanical specifications
Degree of protection IP20
Connection screw terminals
Mass 300 g
Dimensions 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) (W x H x D) , housing type C2
  Height 119 mm
  Width 40 mm
  Depth 115 mm
Mounting on 35 mm DIN mounting rail acc. to EN 60715:2001
Data for application in connection with hazardous areas
EU-type examination certificate TÜV 99 ATEX 1471
  Marking Ex-Hexagon II (1)G [Ex ia Ga] IIC
Ex-Hexagon II (1)D [Ex ia Da] IIIC
Ex-Hexagon I (M1) [Ex ia Ma] I
Supply  
  Maximum safe voltage 253 V AC / 125 V DC (Attention! Um is no rated voltage.)
Input I terminals 1+, 3-: Ex ia
  Voltage Uo 10.1 V
  Current Io 13.5 mA
  Power Po 34 mW (linear characteristic)
Input II terminals 13+, 14- non-intrinsically safe
  Maximum safe voltage Um 40 V (Attention! The rated voltage can be lower.)
Output I, II terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
  Maximum safe voltage 253 V (Attention! The rated voltage can be lower.)
  Contact loading 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load (TÜV 99 ATEX 1471)
Output III terminals 19+, 20- non-intrinsically safe
  Maximum safe voltage Um 40 V (Attention! Um is no rated voltage.)
Output IV terminals 8+, 7- non-intrinsically safe
  Maximum safe voltage 40 V DC (Attention! Um is no rated voltage.)
Interface RS 232
  Maximum safe voltage 40 V (Attention! Um is no rated voltage.)
Galvanic isolation  
  Input I/other circuits safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity  
  Directive 2014/34/EU EN IEC 60079-0:2018 , EN 60079-11:2012
International approvals
FM approval  
  Control drawing 16-538FM-12
IECEx approval  
  IECEx certificate IECEx TUN 04.0007
  IECEx marking [Ex ia Ga] IIC , [Ex ia Da] IIIC , [Ex ia Ma] I
General information
Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
 