General specifications |
Switching function |
complementary |
Output type |
PNP |
Rated operating distance |
5 mm |
Installation |
flush |
Output polarity |
DC |
Assured operating distance |
0 ... 4.05 mm |
Reduction factor rAl |
0.25 |
Reduction factor rCu |
0.15 |
Reduction factor r304 |
0.66 |
Output type |
4-wire |
Nominal ratings |
Operating voltage |
10 ... 30 V DC |
Switching frequency |
0 ... 800 Hz |
Reverse polarity protection |
reverse polarity protected |
Short-circuit protection |
pulsing |
Voltage drop |
≤ 3 V |
Operating current |
0 ... 200 mA |
Off-state current |
0 ... 0.5 mA typ. 0.1 µA at 25 °C |
No-load supply current |
≤ 20 mA |
Switching state indicator |
LED, yellow |
Functional safety related parameters |
MTTFd |
1138 a |
Mission Time (TM) |
20 a |
Diagnostic Coverage (DC) |
0 % |
Compliance with standards and directives |
Standard conformity |
|
|
Standards |
EN IEC 60947-5-2 |
Approvals and certificates |
UL approval |
cULus Listed, General Purpose |
Marine approval |
DNVGL TAA0000160 |
Ambient conditions |
Ambient temperature |
-25 ... 70 °C (-13 ... 158 °F) |
Mechanical specifications |
Connection type |
Connector plug M12 x 1 , 4-pin |
Housing material |
brass, nickel-plated |
Sensing face |
PBT |
Degree of protection |
IP67 |
Dimensions |
|
|
Length |
60 mm |
|
Diameter |
18 mm |
General information |
Use in the hazardous area |
see instruction manuals |