Insulation Resistance |
Test Voltage |
250V/500V/1000V |
Measuring Ranges
(Mid-scale Value) |
100MΩ/200MΩ/400MΩ
(1MΩ) (2MΩ) (4MΩ) |
Output Voltage
on open circuit |
Rated test voltage+20%, -0% |
Nominal Current |
1mA DC min. |
Output Short
Circuit Current |
1.3 mA DC approx. |
Accuracy |
0.1 - 10MΩ/0.2 - 20MΩ/0.4 - 40MΩ
(Accuracy Guaranteed Ranges) ±5% of indicated value |
Continuity |
Measuring Ranges
(Mid-scale Value) |
2Ω/20Ω
(1Ω) (10Ω) |
Output Voltage
on open circuit |
4 - 9V DC |
Measuring Current |
200mA DC min. |
Accuracy |
|±3% of scale length |
General |
Safety Standard |
IEC 61010-1 CAT III 300V Pollution Degree 2
IEC 61010-2-031
IEC 61557-1/2/4 |
IP Rating |
IEC 60529-IP54 |
EMC Standard |
IEC 61326-1 |
Withstand Voltage |
3700V AC for 1 minute |
Power Source |
R6 (AA) (1.5V) × 6 |
Dimensions |
167(L) × 185(W) × 89(D)mm |
Weight |
860g approx. |
Accessories |
7122B (Test leads) Pouch for test leads
8923 (F500mA/600V fuse) × 2
R6 (AA) × 6
Shoulder Strap
Instruction Manual
|