Datalogger Multimeter TES-2732A

Datalogger Multimeter TES-2732A

Category: Multimeter Available
For more information, visit our official website at obsnapinstrument.com

Description

Product Features
Specification

ELECTRICAL SPECIFICATIONS :
Accuracies are ±(...% of reading + ...digits) at 23±5,below 80% RH.
  1. DC Voltage
Range Resolution Accuracy Input Impedance Overload Protection
200mV 0.1mV 0.5%+1 10MΩ 600Vrms
2V 1mV 1100Vrms
20V 10mV
200V 100mV
1000V 1V 0.5%+2
  1. AC Voltage ( 50Hz to 500Hz )
Range Resolution Accuracy Input Impedance Overload Protection
200mV 0.1mV 1%+5 10MΩ 600Vrms
2V 1mV 750Vrms
20V 10mV
200V 100mV
750V 1V 1.2%+5
  1. DC Current
Range Resolution Accuracy Burden Voltage Overload Protection
200uA 0.1uA 1%+1 0.35V 0.5A / 250V Fast
Blow Fuse & Diode
2mA 1uA
20mA 10uA
200mA 100uA
20A 10mA 1.2%+3 0.8V 20A / 380V Fast Blow Fuse
20A for 30sec max.
10A continuity
  1.  AC Current ( 50Hz to 500Hz )
Range Resolution Accuracy Burden Voltage Overload Protection
200uA 0.1uA 1.2%+3 0.35V 0.5A / 250V Fast
Blow Fuse & Diode
2mA 1uA
20mA 10uA
200mA 100uA
20A 10mA 1.5%+5 0.8V 20A / 380V Fast Blow Fuse
20A for 30sec max.
10A continuity
  1.  Resistance ( Ω )
Range Resolution Accuracy Max. Open Circuit Voltage Overload Protection
200Ω 0.1Ω 0.8%+2 3.2V 600Vrms
2KΩ 1Ω 0.5V
20KΩ 10Ω
200KΩ 100Ω
2MΩ 1KΩ
20MΩ 10KΩ 1.5%+3
  1.  Diode ( )
Range Resolution Accuracy Max. Open Circuit Voltage Max. Test Current Overload Protection
  1mV 2%+ 2 3.2V 1.0mA 600Vrms
  1. Continuity ( )
Range Continuity Threshold Max. Open Circuit Voltage Overload Protection
  Continuity audible tone for tested resistance below 30Ω 3.2V 600Vrms
  1. Frequency ( Hz ) ( Test Range 10Hz - 10MHz Auto Range )
Range Resolution Accuracy Sensitivity Overload Protection
2KHz 1Hz 0.5%+2 1.5Vrms 600Vrms
20KHz 10Hz
200KHz 100Hz
2MHz 1KHz
10MHz 10KHz 3Vrms
  1.  Temperature Probe used : K (CA) type sensor
Range Resolution Accuracy
0.1/1     0~ 200    ±(0.5%+1.5 )
 -50~ 0        ±( 1%  +  2 )
200~ 1300  ±( 1%  +  2 )
0.1/1    32~ 200    ±(0.5% + 3 )
  -58~  32     ±( 1%   + 5 )
 200~ 1999  ±( 1%   + 4 )
  1. Capacitance (F)
Range Resolution Accuracy Test Frequency
2000pF 1pF 3%+10 400Hz
200nF 100pF
2uF 1nF
20uF 10nF
 Display:
3 1/2  Digital LCD Display 
Maximum Reading  1999.
Sampling Rate: 2.5 readings per second
Operating/Storage Condition:
0 to 40<80% R.H.
-10 to 60<70% R.H.
Power Source: one 9V Battery
Battery Life Approx. 60hours (Alkaline Battery)
9V Power adaptor jack for long time application
Size & Weight: 180(L)×82(W)×38(H)mm & 365g
Accessories: Test leads ( pair), Spare fuse (0.5A/ 250V ), Battery, Instruction manual, Software, RS-232 Cable, “K” type thermocouple  (TP-K01).
 

More detail about Obsnap Instruments Sdn Bhd
Obsnap Instruments Sdn Bhd
Obsnap Instruments Sdn Bhd Testing Instruments Supplier Malaysia, Measuring Equipments Supply Selangor, Simulation Systems Supplies Kuala Lumpur (KL) ~ Obsnap Instruments Sdn Bhd
Contact Us flagMalaysia