Available in 2 in. and 16 in. through 35 in. sizes, the low-cost HS-series pumps provide high speed, low ultimate pressure, high throughput, high tolerable forepressure, and low backstreaming. The HS-Series diffusion pumps come with full thermal protection and optional quick-cool coils. The 16 in. through 35 in. pumps come with sight glass/fill and drain assemblies, and are available with ASA or ISO flanges.
Pumping Speed, Operating Range Pumping Speed, AVS 4.1 (1963) |
17,300 l/s Air, 21,625 l/s He and H2 32,000 l/s Air |
Maximum Throughput | 30 T-l/s (40 mbar l/s) in operating range, 35 T-l/s (45 mbar-l/s) @ 0.01 torr |
Operating Range | 1.7 x 10-3 to <5 x 10-8 torr (2.3 x 10-3 to <6.5 x 10-8 mbar) |
Maximum Forepressure |
No Load: 0.50 torr (0.65 mbar) Full Load: 0.35 torr (0.45 mbar) |
Recommended Backing Pump | ɛ300 cfm (510 m3/hr) |
Backstreaming Rate, Standard Cold Cap | <7 x 10-4 mg/cm2/min |
Warmup Time | 60 minutes |
Cooldown Time | 180 minutes |
Fluid Charge | 3 U.S. gallons (11.3 liters) |
Electrical Requirements | 3 ph, 50/60 Hz, 240/415/480 VAC |
Pump Power | 24,000 watts |
Cooling Water Requirements | 4 gpm (800 l/hr) at 60-80°F (15-26°C) |
Water Connections | 3⁄8 in. FPT Tee |
Recommended Fluid | DC-704 |
Speed Curve Graph
Pumping Speed/Cold Cap Pumping speed/Halo Baffle Throughput
Description | Voltage | Weight Kg (Lbs) | Part Number | |
HS-32 Pump | Flange Type | |||
Electrical Requirements | ASA | ISO | ||
HS-32 with standard cold cap | 240 V | 612 (1,350) | 76134308 | L5923308 |
HS-32 with halo baffle | 240 V | 612 (1,350) | 76134318 | L5923318 |
HS-32 with standard cold cap | 415 V | 612 (1,350) | 76134326 | L5923326 |
HS-32 with halo baffle | 415 V | 612 (1,350) | 76134336 | L5923336 |
HS-32 with standard cold cap | 480 V | 612 (1,350) | 76134309 | L5923309 |
HS-32 with halo baffle | 480 V | 612 (1,350) | 76134319 | L5923319 |
Accessories | ||||
Water-cooled halo baffle | 16 (35) | K1856332 | ||
Centering ring for ISO foreline flange, 200K | 0.5 (1.0) | IC200SV | ||
O-ring, ISO Inlet flange | 0.5 (1.0) | 78536002 | ||
Instruction manual | 699901140 | |||
Replacement Parts (six heaters required per pump) | ||||
Heater*, 4000 W, 240 V/415 V/ 480 V with leads | 0.5 (1.0) | 647332010 | ||
Heater*, 4000 W, 240 V/415 V/ 480 V no leads used on pumps built before May 90 (*One heater consists of 2-120V heaters, right and left) |
0.5 (1.0) | 647332075 | ||
Heater crush plate (replace one with each new heater) | 4.0 (8.0) | K7246001 | ||
Heater insulator (one required per pump) | 0.5 (1.0) | 75792001 | ||
Heater clamping plate (six required per pump) | K7247001 | |||
Replacement o-ring kit for ASA pumps (kit contains: 1 inlet flange o-ring (buna 45390001), 1 foreline flange o-ring (butyl 2-443), sight glass o-ring and gasket, 8 fill and drain o-rings (Viton 2-213)) | 0.5 (1.0) | K0377167 | ||
Sightglass service kit (pumps built before Oct. 95) | 1.5 (3.0) | F6097301 | ||
ISO inlet flange o-ring | 78536002 | |||
Upper (water) thermal switch (set at 550° F/288 °C) | 0.5 (1.0) | K9050005 | ||
Lower (boiler) thermal switch (set at 220° F/104 °C) | 0.5 (1.0) | K9050004 | ||
Cold cap gasket/grommet (kit of 4) | 0.5 (1.0) | L8839301 | ||
Cold cap nut and follower (2 each) | 0.5 (1.0) | L8840301 | ||
Heater Retrofit Kit (for pumps built before May 90; clamping plates not included) | ||||
HS-32, 240 | 18.16 (40.0) | L6517308 | ||
HS-32, 415 | 18.16 (40.0) | L6517326 | ||
HS-32, 480 | 18.16 (40.0) | L6517309 |