Crack at outer surface of cylinder between 1st & 2nd stage cooling jacket cap

Crack at outer surface of cylinder between 1st & 2nd stage cooling jacket cap

分类: Reciprocating Compressor Cylinder Block 当前有货
欲了解更多详情,请游览我们的官方网站 fpe.com.my

详情

1) To carry out NDT - Liquid penetrant testing to check for surface cracks around the damaged sections
2) To proceed with metal stitching repairs & installation of locks on cracked section.
3) To measure and fabricate of one lot of blind flanges c/w gasket.
4) To carry out surface cleaning of all mating surface for installation of blind flanges.
5) To carry out installation of all required blind flanges.
6) Air leak testing of cylinder block to 2 bar to ensure no leakage. 