详情
General Details
RESmart GII Auto (APAP) adopts advanced sensor technology, automatically tracks patients’ respiratory. The intelligent control system provides patients with reliable therapy of Obstructive Sleep Apnea (OSA).
Reliable stability
-
Innovative tracking technology ensures accurate and comfortable therapy.
-
Unique sensitivity setting offers individual therapy algorithm, makes every user get the most comfort.
-
Ramp capabilities allow a 0-60 minutes time period with adjustable ramp starting pressure.
-
Auto on/Auto off
-
Alert when accidental power off
-
In time alert function when mask/tubing off line
-
Automatic leakage and altitude compensation
-
Unique Delay-off feature protects RESmart from humidity hazard.
-
ICode feature (Web based, Smartphone App) provides the most convenient remote retrieval of sleep data
-
One button to review the treatment information of last day
Ergonomic design
3.5-inch Color LCD Display
With an exquisite control knob, BMC RESmart Generation II Series brings you unsurpassed operational experience.
Blood oxygen saturation and pulse rate can be clearly seen during the course of therapy
Eco Smart heating system with innovative dual water chambers design, Storage Chamber VS Heating Chamber. Optimum Humidity and Temperature are delivered to patient after traveling through the heating chamber.
Accurate water quantity control, with real time compensation from Storage Chamber.
Eco Smart warm up, high efficiency, lower water bills.
Compliance Data is encoded by QR code.
Google play and APP store apps are available.
High reliability-recognition rate up to almost 100%.
High performance-high recognition speed.
More information-less information input.
DC 24V powered and infrared controlled humidifier make user safe and comfortable.Low noise device.
Optional accessories
-
Heated tubing provides constant temperature and relative humidity – Rainout Protection
-
SpO2 Kit
Techical Info
Device Size
Dimensions: 170 × 196 × 118 mm
290 × 196 × 134 mm (with humidifier)
Weight: < 1.5 kg
< 2.5 kg (with humidifier)
Product Use, Transport and Storage
|
Operation |
Transport and Storage
|
Temperature: |
5 to 35°C(41°F to 95°F) |
-25 to 70°C(-13°F to 158 °F)
|
Humidity: |
15 to 93% Non-condensing |
15 to≤93% Non-condensing
|
Atmospheric Pressure: |
760 to 1060 hPa |
760 to 1060 hPa
|
Mode of Operation:
Continuous
Work Mode:
CPAP, AUTO
SD Card:
With a capacity≥2G, the SD card can record patient data and fault information. Furthermore, the language pack stored on the SD card enables you to change the language of the device.
AC Power Consumption:
100 – 240 V AC, 50/60 Hz, 2.0 A max
Type of Protection Against Electric Shock:
Class II Equipment
Degree of Protection Against Electric Shock:
Type BF Applied Part
Degree of Protection Against Ingress of Water:
IP22
Pressure Range:
4 to 20 hPa(in 0.5hPa increments),≤30 hPa under single fault conditions.
Pressure Display Accuracy
±(0.5 hPa+4%)
Ramp:
The ramp time ranges from 0 to 60 minutes
Sound Pressure Level:
<30dB, when the device is working at the pressure of 10 hPa.
Sound Power Level:
<38dB, when the device is working at the pressure of 10 hPa.
SpO2:
Range:0-100%
Pulse Rate:
Range: 40-240 bpm
Wavelengths:
Red: 663 nanometers
Infrared: 890 nanometers
Maximal Optical Output Power:
Less than 1.5 mw maximum average
Tube:
Length: 6 ft. (1.83m)
Heater Settings:
1 to 5(95 to 167°F/ 35 to 75°C)
Maximum Operating Pressure:
30 hPa
Pressure Drop with Humidifier
Humidifier Performance:
Humidity Output: No less than 10 mg H2O/L
Environmental Conditions: Maximum airflow, 35°C, 15% relative humidity
Maximum Delivered Gas Temperature:
<43°C
The Form and the dimensions of the Patient Connection Port:
The 22 mm conical air outlet complies with ISO 5356-1
NOTE: specifications subject to change without prior notice.