Specifications | Range | Basic Accuracy |
---|---|---|
ACV (True rms) | 600V | ±(0.5%rdg+5d) |
AC Current | Model PQ3350-1 (1200A) | ±(0.5%rdg+5d) |
Active Power (kW) | 9.999MW | ±(1%rdg+8d) |
Apparent Power (kVA) | 9999kVA | VA=Vrms x Arms |
Reactive Power (kVAR) | 9999kVAR | VAR= sqr (VA2 -W2) |
Power Factor | 0.0 to +1.00 | ±(1.5%°rdg±8d) |
Frequency | 45-65Hz | 0.1Hz |
Phase | -180.0°~ 0°~ +180.0° | ±1° |
Harmonics | 1 to 99 | ±2% |
Crest Factor | 1.00 to 99.99 | ±(5%+30d) |
Peak AC Voltage accuracy | _ | ±(5%rdg+30d) |
Peak AC Current accuracy | _ | ±(5%rdg+30d) |
Active Power Energy (kWh) | 0mWh to 999,999kWh | |
Reactive Power Energy (kVARh) | 0.0kVARh to 1000MWh | |
Datalogging | 52428 records (single phase)/17476 records (3 phase) | |
Dimensions/Weight | 10.1 x 6.1 x 2.3'' (257 x 155 x 57mm)/ 2.5 lbs (1160g) |