Class 1 Risk Assessment / Environmental System

Class 1 Risk Assessment / Environmental System

分类: Noise Environmental 当前有货
欲了解更多详情,请游览我们的官方网站 allindustrialhygiene.com

详情

Castle / NK002C

Class 1 Risk Assessment / Environmental System

GA6224 (Class 1) Industrial / Environmental Logging Sound Level Meter c/w Calibrator (Dual level, Class 1) (Includes GA690 Barometer) and Data management software and interface cable for use with GA6224

 
The in-depth combination risk assessment package for larger applications.
The meter is ideally equipped for carrying out Noise at Work Risk Assessments, as well as the majority of environmental survey work. The range of parameters measured, the wide measuring capability of the meter and the ease of use, mean that this equipment is suitable for anything from aircraft noise to lawnmower design, and from construction sites to laboratories. Castle GA6224 provides the essential measurements required by the Control of Noise at Work Regulations 2006, including Leq (equivalent continuous level) in A and C weightings, and Cpeak. The meter can data-log any of these parameters in up to 10,000 data-memories, making it more than powerful enough for the task in hand.
 
 
 

Technical Specification

Standards GA6224 : Conforms with IEC 61672-1:2002 Class 1, IEC 60651:1979 and IEC 60804:2000 Type 1 Microphone GA6224 : 7146N 1/2'' electret condenser microphone

Measuring Ranges 27 - 130dB(A), 38 - 130dB(C), 41 - 130dB(F)
Frequency Ranges 20Hz - 20kHz
Time Weighting FAST, SLOW, IMPULSE
Peak Range 50 - 133dB(A), 60 - 133dB(C), 70 - 133dB(F)
Level Range 20 - 80dB, 20 - 90dB, 20 - 100dB, 20 - 110dB, 30 - 120dB, 40 - 130dB
Linearity Range 90dB
Frequency Weighting A, C, FLAT
Measurement Items Lp, LMH, Leq, LAe, Lmax, Lmin, Lx (L5, L10, L50, L90, L95), Peak
Measurement Time 1s, 3s, 5s, 10s, 1min, 5min, 10min, 15min, 30min, 1h, 8h, 24h manual (max: 199h 59m 59s)
Sampling Interval 20.8µs (Leq), 10ms (Lmax, Lmin)
Lx Sampling Interval 100ms
Display LCD with backlight (128×64 dots)
Digital Display Four line, resolution 0.1dB (display update 1s)
Bar Display Display update: 0.1s
Warning Over range: +3dB from upper limited scale
Under Range -0.6dB from lower limited scale
Battery Display Four level display of battery condition
Built-In Memory Approximately 10, 000 samples: 1, 000 sets of results
Built-In Calendar Year/month/day/ hour : minute : second
Pause Pause and a function that deletes preceding 3 or 5 sec. data
Calibration Signal Internal generator (1 kHz sine wave)
AC Output 1Vrms (FS), output impedance: 600O, load impedance > 10kO
DC Output 2.5V (FS), 0.25V/10dB, output impedance: 50O, load impedance > 10kO
RS232 Interface RS-232C (asynchronous); data bits : 8 bits; stop bit : 1 bit; parity : none; baud rate : 4800, 9600, 19200 bps
Power Supply Four 1.5V size-AA batteries or AC adapter
Battery Life Alkaline batteries: 20 hours continuous operation. Use of LCD backlight will shorten battery life (approximately 1/3)
Operating Temperature -10 to + 50 ° C
Humidity 30% to 90% (without condensation)
Size 85(W) × 287(H) × 46(D) mm
Weight 370g (including batteries)

更多 Inter Products Marketing Sdn Bhd 相关资料
Inter Products Marketing Sdn Bhd
Inter Products Marketing Sdn Bhd Industrial Hygiene Products Selangor, Environment Monitoring Equipment Supply Kuala Lumpur (KL), Laboratory Equipment Supplier Malaysia ~ Inter Products Marketing Sdn Bhd