Note: Auxiliary unit 2422 is used together with the main unit 2411 or 2421. It can not be connected to some of AC input models.
| Product Name | 1ch Main Unit | 2ch Main Unit | 2ch Auxiliary Alarm Output Unit | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model Configuration |
|
|
|
| Code | 2411 | 2421 | 2422 |
|---|---|---|---|
| D | Digital switch setting | ||
| S | Screw driver setting | ||
| Code | 2411 | 2421 | 2422 |
|---|---|---|---|
| 1 | H Setting, relay contact output | HL Setting, relay contact output | |
| 2 | L Setting, relay contact output | HH Setting, relay contact output | |
| 3 | H Setting, open collector output | LL Setting, relay contact output | |
| 4 | L Setting, open collector output | HL Setting, open collector output | |
| 5 | -------------------- | HH Setting, open collector output | |
| 6 | -------------------- | LL Setting, open collector output | |
| Code | 2411 | 2421 | 2422 | |
|---|---|---|---|---|
| -- | DC signal |
Note: 2422 is the auxiliary unit, so it accepts no input signal and no specification of ③ is required. |
||
| 02 | DC 0 to 100 mV | |||
| 03 | DC 0 to 1 V | |||
| 04 | DC 0 to 5 V | |||
| 05 | DC 0 to 10 V | |||
| 09 | DC 1 to 5 V | |||
| 00 | Other DC voltage input (60 mV≦00 ≦300 V) | |||
| 22 | DC 0 to 100 μA | |||
| 23 | DC 0 to 1 mA | |||
| 24 | DC 0 to 5 mA | |||
| 25 | DC 0 to 10 mA | |||
| 29 | DC 4 to 20 mA | |||
| 20 | Other DC current input (100 μA≦20 ≦1 A) | |||
| - | AC signal (Effective value rectification type) | |||
| 44 | AC 0 to 150 V rms | |||
| 46 | AC 0 to 300 V rms | |||
| 40 | (100 mV≦40≦300 V) | |||
| 53 | AC 0 to 1 A rms | |||
| 54 | AC 0 to 5 A rms | |||
| 50 | (100 mA≦50≦5 A) | |||
| - | AC signal (Rectification type) | |||
| 73 | AC 0 to 1 A | ※Half wave peak detection system | ||
| 74 | AC 0 to 5 A | |||
| 70 | (100 mA≦70 ≦5 A) | |||
※Connection with 2422, 2ch Auxiliary Alarm Output Unit,is not possible.
| Specification / Model | 2411D/2411S | 2421D/2421S | 2422D/2422S | ||
|---|---|---|---|---|---|
|
D : Digital switch setting S : Screw driver setting |
![]() |
![]() |
![]() |
||
| Dimension (W x H x D mm) excl .Base socket | 28.5 × 72 × 115 | ||||
| Input | DC current / voltage(Moving coil) | ● | ● | - | |
| Process | ● | ● | - | ||
| AC current / voltage | ● | - | - | ||
| Output | Nos. of Alarm | 1point | ● | - | - |
| 2points | - | ● | ● | ||
| Accuracy | Setting (exclude pot.setting) | within ± 0.5 % of Max.value | |||
| Repeatability | within ± 0.1 % | ||||
| Output | Relay | ● | ● | ● | |
| Open collector | ○ | ○ | ○ | ||
| Setting style | Thumb | ● | ● | ● | |
| Potentiometer | ● | ● | ● | ||
| Alarm type (H/L) | H or L fixed | ● | ● | ● | |
| Rating | Relay | 250 V, 0.5 A a.c., 30 V, 2 A d.c. | |||
| Open collector | 50 V, 100 mA d.c. | ||||
| Response |
|
||||
| Function | Hysteresis | ○ | ○ | ○ | |
| Output delay | ○ | ○ | ○ | ||
| Power on delay | ● | ● | ● | ||
| Operating temperature | 0-50°C | ||||
| Operating humidity | 30 - 90%RH (no condensation) | ||||
| AC power supply | 85 – 264 V a.c. | ||||
| DC power supply | 20 – 30 V d.c., 90 – 170 V d.c. | ||||
| Weight | approx. 170 g | ||||
●:Standard, ○:Option