详情
MASSIMOTTO X5 - SAFETY SWITCH FOR SINGLE OR DOUBLE-WING DOORS
Position control for doors / casings on hazardous machinery
Contactless encoded electronic sensor with relay
Category 3 total safety management without an external controller
Suitable for groove profiles and single or double doors
-
Level of performance without an external controller: PL = d
-
Level of performance with AWAX controller: up to PL = e
-
Safety category without an external controller: 3
-
Safety Integrity Level: SIL 2
-
Cycle before dangerous failure: B10d = 2,000,000 at 2A
-
Max. activation distance: 8 mm, 3 mm hysteresis
-
Safety contacts/diagnostics: 2 x NO 2A/48V redundant / 1 x PNP 250mA (X5) or 1xNF (X5.2) auxiliary
-
Detection encoding: mono-code inviolable
-
Indicator: LED indicates code recognition
-
Reset: automatic (SR version) or Manual (AR version)
-
Attachment: 4 tamper-proof M4 screws (optional ref: BH4). Suitable for grooved profiles. Screw caps provided.
-
Mounting position: 1
-
Material: Polycarbonate
-
Electrical connection: 1 M12 connector (X5 version) or 2 M12 connectors (X5.2 version for instant serial connection)
-
Water resistance: IP 67/68
-
Temperature: -25°C to +60°C
-
Marking: screen printed + serial no. for traceability
-
Certification: TÜV Rheinland 01/205/5238/12
-
License Test Mark 968/EL 214.01/12