Parker SSD Drives 512C 16A Single Quadrant DC Drive for 400V, 230V or 110V single/two phase Supply.
Typical Motor Output from 400V AC supply: 4.1kW (5.5HP) at 320V DC for speed and torque control.
Typical Motor Output from 230V AC supply: 2.3kW (3.1HP) at 180V DC.
Typical Motor Output from 110V AC supply: 1.2kW (1.6HP) at 90V DC.
Simple to set-up in analogue, fully-isolated form and ready to run from its default settings.
Dimensions: 160mm Wide x 90mm Deep x 240mm High.
Mounting: Panel mount with screw fixings on 253 x 120mm centres.
Terminals include:-
2 x Analogue Setpoint Inputs including Current Limit Input.
Tacho input (or internal AVF) Feedback.
4 x Analogue Outputs for Ramp, Total Setpoint, Actual Speed and Current.
2 x Digital outputs for Health and Zero Speed (selectable to Zero Setpoint) including + & - 10V power supply for Potentiometers.
Separate AC input to Field Bridge (allows flexibility for the Motor field Voltage).
Input Current: 24A
Input Voltage: 110V/120V, 220V/240V, 380V/415V or 460V/480V single phase/two phase +-10% at 50/60Hz.
Ambient: Rated at 40C.
Ventilation space above and below: 75mm.
Ventilation space at sides: 0mm.
Heat Loss at max output: 50W.
.