Interface | |
Interface | Programmable Incremental |
Programming Functions | PPR (1-16384), Output, Counting Direction |
Configuration Tool | UBIFAST Configuration Tool (Version ≥ 1.6.3) |
Outputs | |
Output Driver | Push-Pull (HTL) |
Output Voltage High Level Push-Pull (HTL) |
> 4 V @ 4.75-9 V Supply Voltage > V-3 V @ 9-30 V Supply Voltage |
Output Voltage Low Level Push-Pull (HTL) | < 0.5 V |
Output Voltage High Level RS422 (TTL) | > 4 V |
Output Voltage Low Level RS422 (TTL) | < 0.5 V |
Maximum Frequency Response | 1 MHz |
Maximum Switching Current | 50 mA per Channel |
Electrical Data | |
Supply Voltage | 4.75 – 30 VDC |
Current Consumption | ≤140mA @ 5V DC, ≤70mA @ 10V DC, ≤40mA @ 24V DC |
Power Consumption | ≤ 1.0 W |
Start-Up Time | < 1 s |
Min. Load Resistance | 120 Ω |
Reverse Polarity Protection | Yes |
Short Circuit Protection | Yes |
EMC: Emitted Interference | DIN EN 61000-6-4 |
EMC: Noise Immunity | DIN EN 61000-6-2 |
MTTF | 280 years @ 40 °C |
Sensor | |
Technology | Magnetic |
Accuracy (INL) | ±0.0878° (≤ 12 bit) |
Duty Cycle | 180° ± 27° (Speed > 100RPM) |
Phase Angle | 90° ± 14° (Speed > 100RPM) |
Environmental Specifications | |
Protection Class (Shaft) | IP65 |
Protection Class (Housing) | IP65 |
Operating Temperature | -30 °C fixed (-22 °F), -5 °C flexible (+23 °F) - +80 °C (+176 °F) |
Humidity | 98% RH, no condensation |