Drastically reduced dust-related defectives by the adoption of Air-Free TRINC. This device has nothing to do with the known shortcomings, “rather increasing dust—related defects,” on Fan—type or BIow—type ionizers.
Specification
Model Name: STATIC-FREE SPACE SMART TRINC-L
Ionizing method: Static-free space method
Ionizing performance: Approximately 5 seconds (measured at center, 600mm off, with a charge plate monitor set at ZOpF without air)
Ion balance control method: Feedback control method by an ion balance sensor
Ion balance: 150V or less
Discharge needle: Titanium needle/ 16 pieces (8×2)
Discharge needle cleaning method: Cleaning each discharge needle with an accessory brush
Needle service life: Approximately 24,000 hours (Needles are replaceable)
Amount of ozone generation: Less than 0.05 ppm (measured at the center part and 200mm off in front of fascia)
Indicators: Green (power) LED lights up indicating the device being in operation. Blue (ION) LED lights up indicating ions being discharged.
Cleaning LED: Yellow (cleaning) LED lights on urges operators to clean the fouled needles.
Alarm indication: Red (error) LED lights up to warn operators of the abnormality in ion discharge volume.
Overhaul-urge indication: Yellow (cleaning) LED flashing to urge operators of an overhaul at the point of actual hours (cumulated) have passed 4 years.
Calculated Lifetime alarm indication: Yellow (cleaning) LED flashing, Blue (ION) LED going off, Red (error) LED lights up, then the actual operation term has passed 5 years (in cumulative hours) and its instrumental lifetime come end.
Alarm interface output: Alarm goes off when an abnormality is confirmed in the ion discharge volume. The alarm output (error) transistor is turned on.
Explosion- protection method: Non- explosion-proof construction
Power consumption: 11.0
Power source AC adaptor (Input: AC 100- 240 V 110%, 50/60 Hz, Output: DC 24 V)
External dimension (Excluding extrusions): Per main body: Width x Depth x Height ; 134 x 102x 210 mm
Weight: 306 gram (main body) Operation temperature, humidity: 0 – 40 °C, 35- 65 RH (No dew condensation allowed)
Accessories: AC adaptor, Ground wire (3 m), brush