Model | AP-AB1601A | AP-AB1602A |
Explosion-proof sign | Ex s ⅡB T4 Gb | Ex s ⅡB T4 Gb |
Explosion-proof certificate No. | GYB16.1549X | GYB16.1549X |
Working Voltage | Power frequency AC4000V | Power frequency AC4000V |
Power | 20W | 20W |
Ion emission | Power frequency AC | Power frequency AC |
Transmitting electrode | SUS | SUS |
Discharge structure | Resistance coupling | Resistance coupling |
Electrode high voltage | ≤4000V | ≤4000V |
Electrode needle combined capacitor | <3.5pF | <3.5pF |
Discharge range | L*W*H(110mm→3000mm) *300mm*100mm |
L*W*H(110mm→3000mm)*300mm*600mm |
Installation distance | 30-100mm | 100-600mm |
Air pressure | —— | ≤0.6MPa |
Compressed air connector | —— | Φ8-G1/8 Red |
Ion balance | ≤|±300V| | ≤|±300V| |
Discharging speed | ≤2.5S (Different test conditions will result in different test data) | ≤2.5S (Different test conditions will result in different test data) |
Working temperature | 0°C – 50°C | 0°C – 50°C |
Working humidity | <70% | <70% |
Bar material | Flame retardant PVC、AL | Flame retardant PVC、AL |
Dimensions | L*W*H(110mm→3000mm) *20.4mm*32mm |
L*W*H(110mm→3000mm)*28.6mm*38.7mm |
Installation accessories | Hex Bolts M4*20 | Hex Bolts M5*20 |
Power supply | AP-AY1603/2603 | AP-AY1603/2603 |
Power cord | 2.5m (Can be customized according to requirements, the maximum length is 8m) | 2.5m (Can be customized according to requirements, the maximum length is 8m) |
Warranty | 1 year | 1 year |
Certification | CE | CE |
NO. | Failure phenomenon | Cause Analysis | Method of exclusion | Remark |
1 | Put the electrode to the ground electrode on the side of the bar to ignite | Reduced surface insulation resistance due to bar volume ash | Power off the cleaning bar | In order to ensure the good performance of this product, according to the use environment and the required electrostatic protection requirements, Regularly use an electrostatic brush, dust-free cotton swab, and dust-free cloth to dip in absolute alcohol to gently remove carbon deposits on the discharge electrode and rod. |
2 | Discharge electrode to other metal grounding body | The bar installation position is too close to other metal grounding bodies | In order to ensure the safe use and power dissipation performance, the installation position of the bar should be moved, and it should be more than 50mm away from other metal grounding bodies. | |
3 | Significantly reduced static elimination performance | Discharge needle contamination and damage | Clean or replace the ion bar | |
Incorrect orientation of the ion bar | Confirm the best installation position | |||
4 | Reduced static elimination performance | There are conductors or other ion bars around the ion bar | Remove (moving) conductors or other ion bars | |
5 | Unable to discharge | Damaged high-voltage connection line | Return to factory | |
Ion bar insulation is damaged | Return to factory | |||
Poor ground / no ground | Check the electrical grounding of ion bars and plant equipment | |||
6 | Product burnout | Ion bar insulation is damaged | Return to factory |