Measuring range - Pressure | -16 ... 16 bar |
Process temperature | -40 ... 105 °C |
Process pressure | -1 ... 400 bar |
Accuracy | 0.065 % |
Materials, wetted parts |
-316L
-Tantalum
-Alloy C276 (2.4819)
-Monel
|
Threaded connection | ¼ - 18 NPT |
Flange connection | ≥ DN32, ≥ 1⅜'' |
Seal material |
-EPDM
-FKM
-Copper
|
Housing material |
-Plastic
-Aluminium
-Stainless steel (precision casting)
-Stainless steel (electropolished)
|
Protection rating |
-IP66/IP68 (0,2 bar)
-IP66/IP67
-IP66/IP68 (1 bar)
|
Output |
-4 … 20 mA/HART
-Profibus PA
-Foundation Fieldbus
-4 … 20 mA
|
Ambient temperature | -40 ... 80 °C |
Scope |
-ATEX / Europe
-FM / USA
-IEC / worldwide
-CSA / USA and Canada
|
Explosion protection |
-Intrinsic safety ''i''
-Flameproof enclosure ''d''
|
Ship approval |
-DNV
-GL
|
Overfill protection |
-WHG
-VLAREM II
|
SIL qualification | SIL2 |
Adjustment |
-PLICSCOM
-PC, PACTware and DTM
-HART-Communicator
-Software (e. g. AMS™, PDM)
-Bluetooth
|
Indication |
-Display/adjustment module PLICSCOM
-VEGADIS 81
-VEGADIS 82
|