详情
The Triplett Model ACDL200 Dual Input True RMS AC Voltage(600V) /Current (200A) Datalogger can datalog up to 131,000 measurements (dual input) or 256,000 measurements (single input) and provides dual channel recording of TRMS Voltage/Voltage or Current/Current or Voltage/Current using a 1 second to 24 hour selectable sampling rate. Features include a multifunction LCD display, real time clock, and Min/Max recalls highest and lowest readings.
Features:
-
Datalog up to 256,000 measurements (single input)or 131,000 measurements (dual input)
-
Dual channel recording of TRMS Voltage/Voltageor Current/Current or Voltage/Current
-
1 second to 24 hour selectable sampling rate
-
Jaw size 0.5'' (12.7mm)
-
Multifunction LCD display
-
Real time clock
-
Min/Max recalls highest and lowest readings
-
Low battery indicator
-
Includes 2 sets of Test Leads, 2 Current Clamp, (4) AAA batteries,AC Adapter, and USB cable
Specifications:
|
ACDL200 |
Channels |
Two, TRMS AC Voltage/Voltage or
TRMS AC Current/Current or
TRMS AC Voltage/Current |
AC Voltage Range
(40-1kHz) |
10 to 600.0V |
Accuracy |
±2%±1V |
AC Current Range (50/60Hz) |
10 to 200.0A |
Accuracy |
±2%±1A |
Datalogger |
256,000 single channel or 131,000 dual channel |
Sample Rate |
Selectable 1 second to 24 hours |
PC Interface |
USB port |
Power |
4 AAA batteries or AC Adapter |
Safety Category |
CAT III-600V |
Dimensions |
4.5 x 2.5 x 1.3'' (114 x 63 x 34mm) |
Weight |
8.7oz (248g) |
更多 LELab Sdn Bhd 相关资料