YSI ProDIGITAL ODO/CT CABLE ASSEMBLY - 1 M

YSI ProDIGITAL ODO/CT CABLE ASSEMBLY - 1 M

分类: CABLE 当前有货
欲了解更多详情,请游览我们的官方网站 hsa-asia.com

Specifications
  • ProDIGITAL ODO/CT Cable Assembly Integral Optical DO and Conductivity Cable Assembly: Accuracy Temperature - ±0.2 °C Dissolved Oxygen - 0 to 200%: ±1% of reading or 1% saturation, whichever is greater 200 to 500%: ±8% of reading 0 to 20 mg/L: ±0.1 mg/L or 1% of reading, whichever is greater 20 to 50 mg/L: ±8% of reading Conductivity - 0 - 100 mS/cm: ±0.5% of reading or .001 mS/cm, whichever is greater 100 - 200 mS/cm: ±1.0% of reading Specific Conductance - 0 - 100 mS/cm: ±0.5% of reading or .001 mS/cm, whichever is greater 100 - 200 mS/cm: ±1.0% of reading User selectable reference temperature (15 to 25 °C; default 25 °C) and compensation coefficient (0 to 4%/°C; default 1.91%) Salinity - ±1.0% of reading or ±0.1 ppt, whichever is greater Total Dissolved Solids (TDS) - Calculated from specific conductance and a user-selectable TDS multiplier (0.30 to 1.00; default 0.65) Seawater Density - Sigma is calculated from salinity, temperature, and pressure (depth) Sigma T is calculated from salinity and temperature Resistivity - ±0.1% Full Scale Equipment used with ProDSS, ProSolo Measurement Range Temperature - -5 to 70 °C (temperature compensation range for DO mg/L measurement: -5 to 50 °C ) Dissolved Oxygen - 0 to 500%, 0 to 50 mg/L Conductivity - 0 to 200 mS/cm Specific Conductance - 0 to 200 mS/cm Salinity - 0 to 70 ppt Total Dissolved Solids (TDS) - 0 to 100 g/L Seawater Density - 0.0 to 50.0 sigma, sigma T Resistivity - 0 to 2 Mohms Resolution Temperature - 0.1 °C or 0.1 °F (user selectable) Dissolved Oxygen - 0.01 mg/L and 0.1%, or 0.1 mg/L and 1% (user selectable) Conductivity - 0.001, 0.01 or 0.1 mS/cm Specific Conductance - 0.001, 0.01, 0.1 mS/cm Salinity - 0.01 ppt Total Dissolved Solids (TDS) - 0.001, 0.01, 0.1 g/L Seawater Density - 0.1 sigma or sigma T Resistivity - 0.001, 0.01, 0.1 Size 0.97 in. width x 10.29 in. length (2.46 cm x 26.14 cm) Unit of Measure Temperature - °C, °F, K; DO - % saturation, % saturation local, mg/L, ppm; Conductivity - S/cm, mS/cm; Specific Conductance - S/cm or mS/cm; Salinity - ppt or PSU; Total Dissolved Solids (TDS) - mg/L, g/L, kg/L; Seawater Density - Sigma, Sigma T; Resistivity - ohm-cm, kohm-cm, Mohm-cm Warranty 2-year probe and cable assembly; 2-year extended warranty ODO sensor caps; 1-year ODO sensor caps
详情

The ODO/CT probe and cable assembly features integral (i.e. built-in) optical dissolved oxygen, conductivity, and temperature sensors and is available in lengths up to 100 meters. It’s perfect for measuring DO in the following applications – estuary, wetland, coastal, aquaculture, or any application requiring accurate, real-time salinity-compensated DO measurements.

The ODO/CT assembly is compatible with the ProSoloProSwap, and ProDSS handhelds (sold separately). Pre-assembled ProSolo ODO/CT kits are available.

 

The ODO/CT has all the advantages of optical dissolved oxygen technology – higher accuracy, less maintenance, no stirring required for accurate measurements, holds calibration longer than membrane covered sensors and is not susceptible to interferences from other gases.

Instrument setup is quick and easy with the integral sensors, which eliminates the need to install sensors before use. The digital technology of the ProDSS allows the handheld to automatically recognize connected sensors, so there is no need to tell the instrument what is connected. 

The ProDIGITAL ODO/CT probe and cable assembly features include:


EXO_University_Icon.pngWant to learn more about the ProDSS? Our new online learning program – ProDSS On-Demand Training – is free to use and ensures all trainees are comfortable going into the field with the ProDSS. We hope to see you in class!

 