Omron Cylindrical Proximity Sensor E2K-X

Omron Cylindrical Proximity Sensor E2K-X

分类: Omron 当前有货
欲了解更多详情,请游览我们的官方网站 province.com.my

详情

Model

E2K-X4ME
E2K-X4MF
E2K-X4MY

E2K-X8ME
E2K-X8MF
E2K-X8M

E2K-X15ME
E2K-X15MF
E2K-X15MY

Sensing distance

4mm ±10%

8 mm ±10%

15 mm ±10%

Set distance *1

0 to 2.8 mm

0 to 5.6 mm

0 to 10 mm

Differential travel

4% to 20% of sensing distance

Detectable object

Conductors and dielectrics

Standard sensing object

Grounded metal plate: 50 × 50 × 1 mm

Response frequency

E and F Models: 100 Hz, Y Models: 10 Hz

Power supply voltage *2
(operating voltage range)

E and F Models: 12 to 24 VDC (10 to 30 VDC)
Y Models: 100 to 220 VAC (90 to 250 VAC)

Current consumption

E and F Models: 15 mA max.

Leakage current

Y Models: 2.2 mA max. (Refer to Datasheet.)

Control
output

Load current

E and F Models: 200 mA max.*2, Y Models: 10 to 200 mA

Residual
voltage

E and F Models: 2 V max. (Load current: 200 mA, Cable length: 2 m),
Y Models: Refer to Engineering Data on Data Sheet.

Indicators

E and F Models: Detection indicator (red), Y Models: Operation indicator (red)

Operation mode
(with sensing object
approaching)

E1, F1, and Y1 Models: NO
E2, F2, and Y2 Models: NC
Refer to the timing charts under I/O Circuit Diagrams on Data Sheet for details.

Protection circuits

E and F Models: Reverse polarity protection, Surge suppressor, load short-circuit
protection, output reverse polarity protection, Y Models: Surge suppressor

Ambient temperature
range

Operating/Storage: -25 to 70°C
(with no icing or condensation)

Operating/Storage: -10 to 55°C
(with no icing or condensation)

Ambient humidity range

Operating/Storage: 35% to 95% (with no condensation)

Temperature influence

±20% max. of sensing distance at 23°C in the operating temperature range

Voltage influence

E and F Models: ±2% max. of sensing distance at rated voltage at rated voltage ±20%
Y Models: ±2% max. of sensing distance at rated voltage at rated voltage ±10%

Insulation resistance

50 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

E and F Models: 1,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case
Y Models: 2,000 VAC, 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z
directions

Shock resistance

Destruction: 500 m/s2 3 times each in X, Y, and Z directions

Degree of protection

IP66 (IEC), in-house standards: oil-resistant

Connection method

Pre-wired Models (Standard cable length: 2 m)

Weight (packed state)

Approx. 65 g

Approx. 145 g

Approx. 205 g

Materials

Case

Heat-resistant ABS

Sensing
surface

Clamping nuts

Polyacetal

Accessories

Instruction manual


 

更多 Province Industrial System Sdn Bhd 相关资料
Province Industrial System Sdn Bhd
Province Industrial System Sdn Bhd Automation Parts Supplier Selangor | PLC Solution Provider KL | Touch Screen HMI Distributor Malaysia ~ Province Industrial System Sdn Bhd