Only 6 mm thick yet provides a sensing distance of 3 mm (TL-W3MC1)
Aluminum die-cast models also available
Model |
TL-W5MD[] |
|
Sensing distance |
5 mm ±10% |
|
Set distance |
0 to 4 mm |
|
Differential travel |
10% max. of sensing distance |
|
Detectable object |
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on |
|
Standard sensing object |
Iron, 18 × 18 × 1 mm |
|
Response frequency *1 |
500 Hz |
|
Power supply voltage |
12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. |
|
Leakage current |
0.8 mA max. |
|
Control |
Load current |
3 to 100 mA |
Residual voltage |
3.3 V max. (under load current of 100 mA with cable length of 2 m) |
|
Indicators |
D1 Models: Operation indicator (red), Setting indicator (green) |
|
Operation mode |
D1 Models: NO |
|
Protection circuits |
Load short-circuit protection, Surge suppressor |
|
Ambient temperature range |
Operating/Storage: -25 to 70°C (with no icing or condensation) |
|
Ambient humidity range |
Operating/Storage: 35% to 95% (with no condensation) |
|
Temperature influence |
±10% max. of sensing distance at 23°C in the temperature range of -25 to 70°C |
|
Voltage influence |
±2.5% max. of sensing distance at rated voltage in the rated voltage ±15% range |
|
Insulation resistance |
50 MΩ min. (at 500 VDC) between current-carrying parts and case |
|
Dielectric strength |
1,000 VAC for 1 min between current-carrying parts and case |
|
Vibration resistance |
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions |
|
Shock resistance |
Destruction: 500 m/s2 3 times each in X, Y, and Z directions |
|
Degree of protection |
IEC 60529 IP67, in-house standards: oil-resistant *2 |
|
Connection method |
Pre-wired Models (Standard cable length: 2 m) |
|
Weight (packed state) |
Approx. 80 g |
|
Materials |
Case |
Heat-resistant ABS |
Sensing surface |
||
Accessories |
Instruction manual |