The forced convection bogie hearth furnaces W 1000/60A - W 8300/85A are used when heavy charges weighing have to be heat-treated. They are ideal for processes such as solution like glass tempering or cooling from glass, for which a good temperature uniformity is crucial. The high-performance air circulation assures that the temperature uniformity achieved throughout the work space is outstanding. A broad selection of additional equipment enables these bogie hearth furnaces to be optimally adapted to suit specific processes.
Model | Tmax | Inner dimensions in mm | Volume | Max. charging weight | Outer dimensions1 in mm | Heating power | Electrical | ||||
---|---|---|---|---|---|---|---|---|---|---|---|
°C | w | d | h | in l | in kg | W | D | H | in kW2 | connection | |
W 1000/.. A | 600 | 800 | 1600 | 800 | 1000 | 800 | 1780 | 2450 | 2350 | 48 | 3-phase |
W 1600/.. A | 600 | 1000 | 1600 | 1000 | 1600 | 1000 | 1920 | 2450 | 2510 | 48 | 3-phase |
W 2200/.. A | 600 | 1000 | 2250 | 1000 | 2200 | 1500 | 1980 | 3100 | 2560 | 96 | 3-phase |
W 3300/.. A | 600 | 1200 | 2250 | 1200 | 3300 | 1900 | 2180 | 3100 | 2750 | 96 | 3-phase |
W 4000/.. A | 600 | 1500 | 2250 | 1200 | 4000 | 2400 | 2480 | 3100 | 2800 | 120 | 3-phase |
W 4800/.. A | 600 | 1200 | 3300 | 1200 | 4800 | 2800 | 2180 | 4380 | 2850 | 120 | 3-phase |
W 6000/.. A | 600 | 1500 | 3300 | 1200 | 6000 | 3700 | 2480 | 4380 | 2900 | 144 | 3-phase |
W 6600/.. A | 600 | 1200 | 4600 | 1200 | 6600 | 4000 | 2280 | 5680 | 2780 | 144 | 3-phase |
W 7500/.. A | 600 | 1400 | 3850 | 1400 | 7500 | 4000 | 2380 | 4930 | 3020 | 144 | 3-phase |
W 8300/.. A | 600 | 1500 | 4600 | 1200 | 8300 | 5200 | 2580 | 5680 | 2950 | 192 | 3-phase |
W 1000/.. A | 850 | 800 | 1600 | 800 | 1000 | 800 | 1780 | 2450 | 2350 | 45 | 3-phase |
W 1600/.. A | 850 | 1000 | 1600 | 1000 | 1600 | 1000 | 1920 | 2450 | 2510 | 45 | 3-phase |
W 2200/.. A | 850 | 1000 | 2250 | 1000 | 2200 | 1500 | 1980 | 3100 | 2560 | 90 | 3-phase |
W 3300/.. A | 850 | 1200 | 2250 | 1200 | 3300 | 1900 | 2180 | 3100 | 2750 | 90 | 3-phase |
W 4000/.. A | 850 | 1500 | 2250 | 1200 | 4000 | 2400 | 2480 | 3100 | 2800 | 110 | 3-phase |
W 4800/.. A | 850 | 1200 | 3300 | 1200 | 4800 | 2800 | 2180 | 4380 | 2850 | 110 | 3-phase |
W 6000/.. A | 850 | 1500 | 3300 | 1200 | 6000 | 3700 | 2480 | 4380 | 2900 | 140 | 3-phase |
W 6600/.. A | 850 | 1200 | 4600 | 1200 | 6600 | 4000 | 2280 | 5680 | 2780 | 140 | 3-phase |
W 7500/.. A | 850 | 1400 | 3850 | 1400 | 7500 | 4000 | 2380 | 4930 | 3020 | 140 | 3-phase |
W 8300/.. A | 850 | 1500 | 4600 | 1200 | 8300 | 5200 | 2580 | 5680 | 2950 | 185 | 3-phase |
1External dimensions vary when furnace is equipped with additional equipment. Dimensions on request. 2Depending on furnace design connected load might be higher |