Sonel MRU-200 Earth Resistance and Resistivity Meter

Sonel MRU-200 Earth Resistance and Resistivity Meter

分类: Ground Testing and Ground Resistance 当前有货
欲了解更多详情,请游览我们的官方网站 mysonel.com

详情

Multifunctional earthing and soil resistivity meter

The Sonel MRU-200 earth resistance and soil resistivity meter for earth resistance and soil resistivity measurements with the use of various methods.

The feature that definitely distinguishes this model from other meters of this kind is the use of all known methods of earth resistance measurement. The measurement can be carried out using the technical 3-pole and 4-wire method, also with additional clamps (multiple earthing), as well as the two-clamp method and the impulse method (earthing impedance measurement).

The use of the two-probe method allows the testing to be carried out without the need for additional auxiliary probes which are driven into the ground. The impact method, on the other hand, is used, among other things, to diagnose lightning protection earthing. It is also used for extensive, multiple and bonded earthing measurements (also underground). The advantage of this method is that there is no need to tamper with the circuit. The impact method enables measurements to be made in accordance with EN 62305 - the need to measure earth impedance.

This is not the end of the extended capabilities provided by the Sonel MRU-200 meter. The device additionally has the function of measuring the resistivity of soil, the continuity of protective and equalising connections, and, with the use of clamps, also leakage or fault currents.

Apart from the large number of functions and many measurement possibilities, the MRU-200 meter deserves recognition also for the high accuracy of the obtained results. Measuring range - measurements in accordance with EN 61557 - from as low as 0.30 Ω.

Measurement methods

Additional features

Application

MRU-200 meter was created for the most difficult working conditions. It generates a measuring current exceeding 200 mA, which provides effective measurements of grounding of energy objects such as transformer stations and power stations.

Thanks to the methods using clamps, it is not necessary to disconnect the control connectors, which is sometimes a very tedious operation. This plays a special role when performing works on objects exposed to weather conditions, where the connecting elements are sometimes corroded or tarnished.

The graphical user interface provides clear readings and explicit messages. This translates into quick, trouble-free service.

Impulse method

MRU-200 may be used to test earthing of lightning protection systems, as this meter is able to simulate the conditions occurring during a lightning strike – it generates current with a standardized pulse leading edge and a time to half-peak. Available impulse ramps include 4/10 μs, 8/20 μs, 10/350 μs.

Compatible with ERP-1 adapter

ERP-1 adapter allows user to test earthing systems using flexible clamps. This is particularly useful, e.g. in case of lattice towers – there is no need to switch off the line or disconnect control connectors. Proprietary algorithm allows user to check the current direction in the individual measurements and facilitates damage detections, e.g. corroded steel strip (hoop).

Capabilities

The measuring methods available in the device allow for comprehensive control of working and protective grounding. The calibration function of the test leads eliminates the influence of their resistance on the result. However, this is just the beginning.

Memory and results

The results can be saved to the device’s memory. It is divided into 10 banks of  99 cells, each corresponding to one measurement. These results can be easily transferred to the Sonel Reader software for archiving or subsequent analysis and research.

Bluetooth wireless interface may be used to transfer measurement results to PC software or to a mobile phone with dedicated app – Sonel MRU Mobile. This provides not only data archiving function, but further data transfer – directly from the measurement site via an e-mail.



Technical Data
 
Measurement functions Measurement range Display range Resolution Accuracy
Interference voltage 0 V…100 V 0 V…100 V 1 V ±(2% m.v. + 3 digits)
Resistance of earth connection and equipotential bonding 0.045 Ω…19.99 kΩ acc. to EN 61557-4 0.00 Ω…19.9 kΩ from 0.001 Ω from ±(2% m.v. + 2 digits)
Earth resistance        
3-pole and 4-wire method 0.100 Ω…19.99 kΩ acc. to EN 61557-5 0.00 Ω…19.9 kΩ from 0.001 Ω from ±(2% m.v. + 2 digits)
3-pole + clamp method 0.120 Ω…1999 Ω acc. to EN 61557-5 0.00 Ω…1999 Ω from 0.001 Ω ±(8% m.v. + 3 digits)
two-clamp method 0.00 Ω…149.9 Ω 0.00 Ω…149.9 Ω from 0.01 Ω from ±(10% m.v. + 3 digits)
impulse method 4/10 μs, 8/20 μs, 10/350 μs pulse 0.0 Ω…300 Ω 0.0 Ω…300 Ω from 0.1 Ω ±(2.5% m.v. + 3 digits)
auxiliary electrodes resistance 0 Ω…19.9 kΩ 0 Ω…19.9 kΩ from 1 Ω ±(5% (RE +RH+RS) + 8 digits)
Earth resistivity 0.0 Ωm…999 kΩm 0.0 Ωm…999 kΩm from0.1 Ωm Depends on the accuracy of the RE 4p measurement, but not less than ±1 digit
Leakage current 0.1 mA…300 A 0.1 mA…300 A from 0.1 mA from ±(5% m.v. + 5 digits)

 

“m.v.” - measured value

 

Parameter Value
Net weight (kg) 1.8
Package weight (kg) 8
Package width (cm) 50
Package height (cm) 19
Package length (cm) 32

更多 Sonel 相关资料
Sonel
Sonel Measuring Instruments Malaysia, Electrical Test Equipment, Thermovision Cameras ~ Sonel