Model |
SJ-E132A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/ |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level alarm |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm |
||||
Alarm output |
||||
Major features |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa *2 (recommended air pressure of 0.2 MPa) |
|||
Effective length |
1380 mm *3 |
|||
Total length |
1280 mm |
|||
No. of electrodes |
21 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |